Cabling lines and trunks Page 271 of 456
Table 39
NT8D37 IPE Module: NT8D15 E&M Trunk Card
Pair | Pin numbers | Pair color | Unit |
|
|
|
|
3T/3R | 38/13 |
| 3 |
E/M | 40/15 |
|
Note: Each of the following I/O panel connectors is cabled as shown
above: connectors A, B, C, D, E, F, G, H, K, L, M, N, R, S, T, and U. These connectors are associated with backplane slots 0 through 15, sequentially.
Table 40
NT8D37 IPE Module: NT8D15 E&M Trunk Card
Lead designations |
|
|
|
| |
|
|
|
|
| |
Type 1 | Type 2 | Pin numbers | Pair color | Unit | |
|
|
|
|
| |
TA/TB | TA/TB | 26/1 |
| ||
RA/RB | RA/RB | 27/2 | 0 | ||
E/M | EA/EB | 28/3 | |||
| |||||
ESC/ESCG | MA/MB | 29/4 |
| ||
|
|
|
|
| |
TA/TB | TA/TB | 30/5 |
| ||
RA/RB | RA/RB | 31/6 | 1 | ||
E/M | EA/EB | 32/7 | |||
| |||||
ESC/ESCG | MA/MB | 33/8 |
| ||
|
|
|
|
| |
TA/TB | TA/TB | 34/9 |
| ||
RA/RB | RA/RB | 35/10 | 2 | ||
E/M | EA/EB | 36/11 | |||
| |||||
ESC/ESCG | MA/MB | 37/12 |
| ||
|
|
|
|
|
Communication Server 1000M and Meridian 1 Large System Installation and Commissioning