Installing a Signaling Server Page 447 of 456
Verifying a successful configuration
To ensure that the Signaling Server Ethernet connections (for the ELAN and TLAN subnets) are configured correctly, perform a ping test to one or more of the other devices connected to the network, particularly the Call Server.
Procedure 82
Verifying the Signaling Server Ethernet connection
1Log in to the Signaling Server, using Procedure 81 on page 446.
2Ping the IP address of the Signaling Server. Enter the command: ping x.x.x.x
Where x.x.x.x is the Signaling Server ELAN network interface IP address.
3Ping the IP address of the Call Server. Enter the command: ping x.x.x.x,3
Where x.x.x.x is the Call Server ELAN network interface IP address.
4If desired, repeat step 3 for other devices connected to the network.
End of Procedure
Testing the Leader Signaling Server
Configure two IP Phones to register to the Signaling Server on its temporary node. These IP Phones must be provisioned on the Call Server. Refer to Communication Server 1000E: Installation and Commissioning
Large System Installation and Commissioning
Communication Server 1000M and Meridian 1 Large System Installation and Commissioning