Page 400 of 456 Installing a Signaling Server

Installing the software

To install software and enter basic system configuration parameters on an IBM X306m or HP DL320-G4 Signaling Server, complete Procedure 78.

Procedure 78

Installing Signaling Server software

Upon completion of Step 1, this procedure takes approximately 45 minutes to complete.

1From your Planning and Engineering group, obtain the following network and IP Telephony data for this Signaling Server:

node ID for the IP Telephony node

node IP address for the IP Telephony node

hostname for the Signaling Server

ELAN network interface IP address, Subnet mask, and Gateway

TLAN network interface IP address, Subnet mask, and Gateway

ELAN network interface IP address of the Call Server

Primary and Alternate NRS IP addresses for this networked system. Refer toIP Peer Networking: Installation and Commissioning (NN43001-313)

NRS role, if applicable. Refer to IP Peer Networking: Installation and Commissioning (NN43001-313)

2Boot the Signaling Server from the Removable Media Device (RMD):

For IBM X306m, HP DL320-G4, or Nortel ISP1100 Signaling Servers, insert the CS 1000 Release 5.5 Signaling Server Software CD into the CD drive and press the RST button on the front panel of the Signaling Server to trigger a cold boot. This forces the Signaling Server to boot from the CD.

For a Nortel CP PM Signaling Server, insert the CS 1000 Release 5.5 Signaling Server Software CF card into the faceplate CF drive and press the RST button on the faceplate of the Signaling Server to trigger a cold boot. The CP PM System BIOS Configuration screen appears (see Figure 142) with an instruction to press F to force the Signaling Server to boot from the CF card.

NN43021-310 Standard 02.01 December 2007

Page 400
Image 400
Nortel Networks 1000M warranty Installing the software, Procedure Installing Signaling Server software