Page 400 of 456 Installing a Signaling Server
Installing the software
To install software and enter basic system configuration parameters on an IBM X306m or HP
Procedure 78
Installing Signaling Server software
Upon completion of Step 1, this procedure takes approximately 45 minutes to complete.
1From your Planning and Engineering group, obtain the following network and IP Telephony data for this Signaling Server:
•node ID for the IP Telephony node
•node IP address for the IP Telephony node
•hostname for the Signaling Server
•ELAN network interface IP address, Subnet mask, and Gateway
•TLAN network interface IP address, Subnet mask, and Gateway
•ELAN network interface IP address of the Call Server
•Primary and Alternate NRS IP addresses for this networked system. Refer toIP Peer Networking: Installation and Commissioning
•NRS role, if applicable. Refer to IP Peer Networking: Installation and Commissioning
2Boot the Signaling Server from the Removable Media Device (RMD):
•For IBM X306m, HP
•For a Nortel CP PM Signaling Server, insert the CS 1000 Release 5.5 Signaling Server Software CF card into the faceplate CF drive and press the RST button on the faceplate of the Signaling Server to trigger a cold boot. The CP PM System BIOS Configuration screen appears (see Figure 142) with an instruction to press F to force the Signaling Server to boot from the CF card.