Page 434 of 456 Installing a Signaling Server
Figure 182
Stand-alone Signaling Server configuration
CS 1000 Signaling Server Software Install Tool
=====================================================================
Please define the data networking parameters for this Standalone Signaling Server. Note that the ELAN parameters are necessary for management access (e.g. SNMP).
Hostname | : SS_SA |
ELAN IP | : 192.168.10.20 |
ELAN subnet mask: 255.255.255.0
ELAN gateway IP : 192.168.10.1
TLAN IP | : | 192.168.20.20 | |
TLAN | subnet mask: | 255.255.255.0 | |
TLAN | gateway IP : | 192.168.20.1 |
10Enter the data networking and IP telephony parameters for the Signaling Server, as prompted.
•If this is a Leader Signaling Server, enter the parameters for the Node, ELAN network interface, TLAN network interface, and Call Server as required. See Figure 164 on page 419. For the Call Server:
—If installing the Signaling Server at an office that is not a branch office, enter the ELAN network interface IP address of the Call Server.
—If installing the Signaling Server at a branch office, enter the ELAN network interface IP address of the MG 1000B Core.
•If this is a Follower Signaling Server, enter the Hostname of the Leader Signaling Server. The IP telephony parameter configuration screen appears (Figure 183 on page 435).