Page 340 of 456 Performing acceptance tests
On the LCD displays on the Cards:
•Following the “Selftest Complete” message, watch the LCD for the message “IOP in Slot 17.”
•Watch the LCD for the message “Loading Disk OS.”
•When the sysload is complete, the system terminal displays DONE and the system automatically invokes the initialization program.
The following functions occur when the initialization is complete:
•The column LED should go out.
•The major alarm indication should disappear from all attendant consoles.
•The system automatically runs the programs in the midnight routine.
2Press the return key on the system terminal to monitor the progress of the midnight routines until the OVL111 BKGD response is received.
End of Procedure
Testing the system terminal and system monitor
Use Procedure 62 to test the system terminals connected to the Large System.
Procedure 62
Testing system terminal and system monitor
1Log into the system: LOGI (password)
2Enter the program and check the status of the system monitor:
LD 37
STAT XSM
3Test the terminal:
TTY x “x” is the device number assigned to the system terminal
The system terminal should display
ABCDEFGHIJKLM
NOPQRSTUVWXYZ