Page 368 of 456 Adding a module to a column

5Connect the power and system monitor cables in the module:

a.Connect the power connectors to the pedestal and to the module above (see Figure 125 on page 366 and Figure 127 on page 369).

b.Attach the frame ground wires to the frame ground post at the base of the module.

c.Connect the system monitor cable from the pedestal to connector J1 on the module being added.

d.Connect the system monitor cable from connector J2 in the module being added to J1 in the module above.

6Set all circuit breakers in the pedestal to ON.

7Reinstall the system monitor in the pedestal:

a.Reconnect the RJ11 cable to J6, then the cable to J3. Reinstall the system monitor.

b.If the column houses the master system monitor, load LD 37, and software re-enable the associated SDI port:

LD 37

 

ENL TTY x

enable the device associated with the port

****

exit LD 37

8Replace all module covers and the pedestal grill.

End of Procedure

NN43021-310 Standard 02.01 December 2007

Page 368
Image 368
Nortel Networks 1000M warranty Enl Tty, Exit LD