Cabling Common Equipment in a Single Group system Page 193 of 456
2NT4N48 System Utility card. The System Utility card is located in slot c15.
3NT4N39AA Call Processor PIV (CP PIV). This card is located in the slot marked CP.
Cabling the Core side
This section describes installation of the Core cables. Table 20 lists
Table 20
|
| Number required |
Order Code | Description | per system |
|
|
|
NT4N88AA | COM1 (DTE/terminal) | 2 |
NT4N88BA | COM2 (DCE/modem) | 2 |
NT4N90BA | Ethernet (CP PIV card to I/O panel) | 2 |
NTRC17BA | Crossover Ethernet cable (Core to Core) | 1 |
customer supplied | Standard Ethernet cable (I/O Panel to LAN | 2 |
| switch) |
|
| ||
Note: If there is no connection to a LAN, connect the two LAN 1 connectors using the | ||
NTRC17BA crossover cable. |
| |
|
|
|
Table 21 |
|
|
Factory installed Core cables (internal) |
| |
|
|
|
|
| Number required |
Order Code | Description | per system |
|
|
|
NT4N4405 | Shelf Power: Net backplane to Core backplane | 2 |
NT4N29AA | cCNI to 3PE Core/Net shelf cable | 4 |
NT4N89AA | System Utility Card to XSM (see Figure 79) | 2 |
|
|
|
Communication Server 1000M and Meridian 1 Large System Installation and Commissioning