Nortel Networks 1000M warranty BL/W Remalma

Models: 1000M

1 458
Download 458 pages 7.95 Kb
Page 162
Image 162

Page 162 of 456 Configuring the system monitor

Note 1: The system monitor to MDF cable is available in three lengths: NT8D46BH (9.75 m/32 ft), NT8D46EH (30 m/100 ft), and NT8D46DH (45 m/150 ft).

Note 2: If additional contact closures are required through the J3 REMALMA or REMALMB leads (for a hard alarm in case a column loses power, for example), additional system monitor to MDF cables can be ordered.

Table 12

NT8D22 System Monitor – pin assignments at J3

Pin

Direction

Color

Signal name

Description

 

 

 

 

 

1

out

BL/W

REMALMA

Remote major alarm (connect for external alarm)

2

out

OR/W

REMALMB

Remote major alarm return (connect for external

 

 

 

 

alarm)

3

out

GR/W

CE-SYSLT

CE system line transfer (upgraded systems only)

4

BR/W

MDF0/GND

MDF return (ground)

5

in

SL/W

CEALMIN

CE alarm (upgraded systems only)

6

BL/R

SYSLTIN

System line transfer in (upgraded systems only)

7

out

W/BL

LFBEN

Line forced bypass enable (connect for PFTU

 

 

 

 

operation)

8

out

W/OR

LFBENR

Line forced bypass enable return (connect for

 

 

 

 

PFTU operation)

9

W/GR

GND

Ground

Note: Pins 6, 8, and 9 should be connected and grounded at the MDF.

NN43021-310 Standard 02.01 December 2007

Page 162
Image 162
Nortel Networks 1000M warranty BL/W Remalma