Page 330 of 456 Powering up the system and initial loading
At this point the system should reload and initialize.
End of Procedure
Testing Core/Net 1 and Core/Net 0
LD 137 modifications
The CMDU/MMDU commands are not applicable to CP PIV. Instead, the following commands are introduced in LD 137.
•STAT FMD
display text: Status of both Fixed Media Devices (FMD)
command parameter: none
•STAT FMD 0/1
display text: Status of the specified Fixed Media
Device
command parameter: “core #” with values of 0 or 1
•STAT RMD
display text: Status of both Removable Media Devices (RMD)
command parameter: none
•STAT RMD
display text: Status of the specified Removable Media
Device
command parameter: “core #” with values of 0 or 1
Procedure 56
Testing Core/Net 1
1Perform a redundancy sanity test:
LD 135 | Load program |
STAT CPU | Get status of CPU and memory |
TEST CPU | Test CPU |
2Check the LCD states: