Page 330 of 456 Powering up the system and initial loading

At this point the system should reload and initialize.

End of Procedure

Testing Core/Net 1 and Core/Net 0

LD 137 modifications

The CMDU/MMDU commands are not applicable to CP PIV. Instead, the following commands are introduced in LD 137.

STAT FMD

display text: Status of both Fixed Media Devices (FMD)

command parameter: none

STAT FMD 0/1

display text: Status of the specified Fixed Media

Device

command parameter: “core #” with values of 0 or 1

STAT RMD

display text: Status of both Removable Media Devices (RMD)

command parameter: none

STAT RMD

display text: Status of the specified Removable Media

Device

command parameter: “core #” with values of 0 or 1

Procedure 56

Testing Core/Net 1

1Perform a redundancy sanity test:

LD 135

Load program

STAT CPU

Get status of CPU and memory

TEST CPU

Test CPU

2Check the LCD states:

NN43021-310 Standard 02.01 December 2007

Page 330
Image 330
Nortel Networks 1000M warranty Testing Core/Net 1 and Core/Net, Procedure Testing Core/Net