Reviewing Core/Net module placement

Core/Net modules are installed side-by-side on top of separate pedestals, for power and cooling redundancy. Core/Net 1 is always on the left. Core/Net 0 is always on the right (see Figure 87 on page 211).

Reviewing required Core cards

All Core cards are installed in the factory. See Table 26 on page 210 for the Core card requirements for each Core/Net module. Refer to “System equipment – UEMs” on page 38 for module and card descriptions.

Table 26

Required Core cards (minimum per Core/Net module)

 

 

Number required per

Backplane

Order Code

Description

Core/Net module

side

 

 

 

 

NT4N65

cCNI: cPCI Core Network Interface

1 to 41

front

 

Card

 

 

 

 

 

 

NT4N48

System Utility Card

1

front

 

 

 

 

NT4N39AA

CP PIV Call Processor Card

1

front

 

(512 MB memory)

 

 

 

 

 

 

N0026096

MMDU blank faceplate

1

front

 

 

 

 

Note 1: Each cCNI card supports two Network groups. The number of cCNI cards in each system depends on the number of Network groups installed in the system. See the System Layout plan to determine the number and placement of cCNI cards.