Page 420 of 456 Installing a Signaling Server
Figure 165
Stand-alone Signaling Server configuration
CS 1000 Signaling Server Software Install Tool
=====================================================================
Please define the data networking parameters for this Standalone Signaling Server. Note that the ELAN parameters are necessary for management access (e.g. SNMP).
Hostname | : SS_SA |
ELAN IP | : 192.168.10.20 |
ELAN subnet mask: 255.255.255.0
ELAN gateway IP : 192.168.10.1
TLAN IP | : | 192.168.20.20 | |
TLAN | subnet mask: | 255.255.255.0 | |
TLAN | gateway IP : | 192.168.20.1 |
14Enter the data networking and IP telephony parameters for the Signaling Server, as prompted. The IP information applies to a temporary IP Telephony node, to ensure that the existing node is not affected. The entry of data networking and IP telephony parameters also preconfigures the IP Telephony node files. After the Signaling Server software installation, the node files are imported into Element Manager for further configuration (see "Importing IP Telephony nodes" in Signaling Server: Installation and Commissioning
•If this is a Leader Signaling Server, enter the parameters for the Node, ELAN network interface, TLAN network interface, and Call Server as required.
—If installing the Signaling Server at an office that is not a branch office, enter the ELAN network interface IP address of the Call Server.
—If installing the Signaling Server at a branch office, enter the ELAN network interface IP address of the MG 1000B Core.
•If this is a Follower Signaling Server, enter the Hostname of the Leader Signaling Server. Then go to step 16 on page 423.
•If this is a