Page 182 of 456 Connecting a system terminal or modem

3At the local end, configure the modem.

Follow the manufacturer’s instructions to set the modem for 9600 baud, auto answer, dumb mode, command recognition OFF, command echo OFF.

4At the local end, connect an NT8D95 cable to the SDI port on the I/O panel in the rear of the module and to the modem.

5At the local end, connect the cable from the modem to an RJ11 telephone jack. If a cable is required, connect an NT8D46 cable to the modem and to the RJ11 jack.

6To communicate with a COM2 port, switch the cable from the modem to the port as needed.

For debugging or monitoring, connect the cable to the active CPU at J21 on the I/O panel in the rear of the cPCI Core/Network Module.

For patch downloading, connect the cable to the inactive CPU at J21 on the I/O panel in the rear of the cPCI Core/Network Module.

End of Procedure