Page 254 of 456 Cabling network modules and loops

Table 33

NT8D04 network loop configurations

 

FROM

TO

 

 

 

 

 

 

 

 

Superloop

Faceplate

Controller

 

Backplane

 

network card

connector

card

 

connector

 

 

 

 

 

 

One segment per superloop

NT8D04 #1

J2

NT8D01AC #1

 

SL0

 

 

 

 

 

 

 

NT8D04 #2

J2

NT8D01AC #1

 

SL1

 

 

 

 

 

 

 

NT8D04 #3

J2

NT8D01AC #1

 

SL2

 

 

 

 

 

 

 

NT8D04 #4

J2

NT8D01AC #1

 

SL3

 

 

 

 

 

 

Two segments per superloop

NT8D04 #1

J2

NT8D01AD #1

 

SL0

 

 

 

 

 

 

 

NT8D04 #2

J2

NT8D01AD #1

 

SL1

 

 

 

 

 

 

Four segments per superloop

NT8D04 #1

J2

NT8D01AD #1

 

SL0

 

 

 

 

 

 

Eight segments per superloop

NT8D04 #1

J2

NT8D01AD #1

 

SL0

 

 

 

 

 

 

 

NT8D04 #1

J1

NT8D01AD #2

 

SL0

 

 

 

 

 

 

One segment per superloop/

NT8D04 #1

J2

NT8D01AD #1

 

SL0

three segments per another

 

 

 

 

 

NT8D04 #2

J2

NT8D01AD #1

 

SL1

superloop

 

 

 

 

 

 

 

 

 

 

 

 

Four segments per superloop/

NT8D04 #1

J2

NT8D01AC #1

 

SL0

four segments per another

 

 

 

 

 

NT8D04 #2

J2

NT8D01AC #2

 

SL0

superloop

 

 

 

 

 

 

 

NT8D04 #2

J1

NT8D01AC #1

 

SL1

 

 

 

 

 

 

Note: NT8D01AC is a controller-4

 

 

 

 

NT8D01AD is a controller-2

 

 

 

 

 

 

 

 

 

 

NN43021-310 Standard 02.01 December 2007