Connecting a system terminal or modem Page 177 of 456

Connecting a switch box and terminal to

SDI and COM1 ports

Use Procedure 20 to connect COM1 ports to a switch box and a terminal (see Figure 70 on page 176 and Figure 71 on page 178).

Procedure 20

Connecting a switch box and terminal to the SDI and COM1 ports

1Set the terminal to 9600 baud, 7 data, space parity, one stop bit, full duplex, XON.

2Connect an NT8D95 cable to the terminal and to the switch box.

3Connect NT8D95 cables to a matching connector on the switch box. When using an A0377992 ABCDE box, connect:

CPU 0 to connector A.

CPU 1 to connector B.

The SDI port to connector D (connector C is common).

4Connect NT8D95 cables from the switch box to J25 on the I/O panel in the rear of each cPCI Core/Network Module.

5Connect an NT8D95 cable from the switch box to the I/O panel slot for the SDI card.

6To communicate with the system in general, set the switch box to the SDI port. To communicate directly with a COM1 port, switch the cable as needed.

End of Procedure

Communication Server 1000M and Meridian 1 Large System Installation and Commissioning

Page 177
Image 177
Nortel Networks 1000M warranty Connecting a switch box and terminal to SDI and COM1 ports, End of Procedure