Cabling Common Equipment in a Multi Group system Page 227 of 456

Table 31

Required cables (Part 2 of 2)

Cable type

Quantity

Order Code

Description

 

 

 

 

 

 

NTRC46BB

1.65 m to 2.4 m (5.5 ft. to 8 ft)*

 

 

NTRC46CB

6.7 m (22 ft)*

Clock to Clock

1 per system

NTRC49AA

1.8 m (6 ft)

 

 

NTRC49BA

6 m (20 ft)

FIJI to FIJI Sync

1 per network group

NTRC47AA

1.5 m (5 ft)

* Indicates the lengths of the two “Y” terminations.

WARNING

The shortest Fiber Cable must always be used.

The cables from Group 0 to Group 1 must always be the same length as the cables from the last group back to Group 0

The delta between the lengths of each fiber ring from Group 0 to any other group must not exceed 15 m (50 ft). Rings are directional. Ring 0 is ascending and Ring 1 is descending.