Cabling lines and trunks Page 263 of 456

Media Gateway cabling requirements

Media Gateways require the following:

Each Media Gateway and Media Gateway Expander requires up to four

25-pair cables:

one 25-pair cable for each slot that is equipped with a trunk or line circuit card

one 25-pair cable for each NTAK03 or NTAK02 card not using the NTAK19EC 2-port SDI cable or the NTAK19FB 4-port SDI cable

When Ethernet connections are used instead of traditional cabling, use the Media Card Input/Output Adapter.

For the NTAK09 1.5 Mbit DTI/PRI circuit card, use the NTBK04 cable.

For the NTAK10 2.0 Mbit DTI circuit card, NTAK79 2.0 Mbit PRI circuit card, and NTBK50 2.0 Mbit PRI circuit card, use the NTBK05 cable.

Cabling an IPE Module or Media Gateway

Follow Procedure 45 to cable IPE Modules (NT8D37), Media Gateways, or Media Gateway Expanders.

Note: The corner vertical channels in the rear of the IPE module are outside of the EMI shield. Cables in those vertical channels must be shielded, and must enter and exit the EMI-shielded area through I/O panels and adapters.

DANGER OF ELECTRIC SHOCK

Tip, ring, A, B, E, M, ESC, and ESCG connections may be considered to be Telecommunication Network Voltages (TNV).

Communication Server 1000M and Meridian 1 Large System Installation and Commissioning

Page 263
Image 263
Nortel Networks 1000M warranty Cabling an IPE Module or Media Gateway, Media Gateway cabling requirements