256

Troubleshooting

 

 

 

 

 

Symptom

Advice

 

 

 

Fader movements are inconsistent.

Try calibrating the faders. See “Calibrating the Faders” on page 204

for more information.

 

 

 

 

 

 

 

This warning message appears if digital signals from the Digital Stereo

DIGITAL IN Sync Error message

Coaxial In or Option I/O inputs are not wordclock synchronized with

the 01V. Make sure that all digital equipment is wordclock synchro-

appears.

 

 

nized to a common wordclock source. See “Setting the Wordclock”

 

 

 

 

on page 209 for more information.

 

 

 

UNLOCK appears in the Fs window

Make sure the external wordclock source is turned on and that the

cable carrying the wordclock signal has not been disconnected. See

of SETUP page 1.

“Setting the Wordclock” on page 209 for more information.

 

 

 

 

 

Cannot transmit or receive MIDI

On MIDI page 1, check the following settings: PORT, Tx CH, Rx CH,

and the Tx and Rx switches for Program Change, Control Change,

messages.

etc. See “MIDI Setup” on page 224 for more information.

 

 

 

 

 

 

 

Make sure that the 01V is configured to receive Program Change mes-

 

 

sages and that the MIDI Channels of the 01V and transmitting device

 

 

match. See “MIDI Setup” on page 224 for more information.

 

 

 

MIDI Program Change messages

Perhaps the Program Change being transmitted is not assigned to an

01V scene memory? Check the mix scene to Program Change assign-

don’t recall mix scenes.

ment table. See “Program Change Scene Recall” on page 227 for

 

 

 

 

more information.

 

 

 

 

 

If the scene memory assigned to the received Program Change con-

 

 

tains no data, it cannot be recalled.

 

 

 

 

 

Make sure that the 01V is configured to receive Control Change mes-

 

 

sages and that the MIDI Channels of the 01V and transmitting device

MIDI Control Change messages

match. See “MIDI Setup” on page 224 for more information.

 

Perhaps the Control Change being transmitted is not assigned to an

don’t control mix parameters.

 

 

01V parameter? Check the parameter to Control Change assignment

 

 

table. See “Control Change Parameter Control” on page 229 for more

 

 

information.

 

 

Cannot receive MIDI Bulk Dump

Make sure that the BULK Rx switch on MIDI page 1 is turned on. See

data.

 

“MIDI Setup” on page 224 for more information.

 

 

 

Controls have no effect on the 01V.

Perhaps the Local Control function on MIDI page 5 is turned off? See

“Local Control” on page 234 for more information.

 

 

 

 

 

MMC commands have no effect.

Make sure the device number matches that of the MMC-compatible

recorder. See “MIDI Machine Control” on page 236 for more informa-

 

 

tion.

 

 

 

01V—Owner’s Manual

Page 266
Image 266
Yamaha 01v owner manual 256