Setting the Metering Point 85
01V—Owner’s Manual
Setting the Metering Point
The metering points for input channels 1 through 16 and the effects returns can be set
to either PRE EQ or PRE FADER. For the stereo output, aux send, and bus out meters
it can be set to either POST EQ or POST ON. These settings do not affect the main ste-
reo meters, which always meter POST ON signals.
1. Use the [HOME] button to locate HOME page 5, as shown below.
2. Use the cursor buttons to select the switches, and the PARAMETER wheel,
[–1/DEC], [+1/INC], and [ENTER] buttons to set them.
INPUT—Used to set the meter source points for input channels 1 through 16 and the
effects returns to either PRE EQ or PRE FADER.
OUTPUT—Used to set the meter source points for the stereo output, aux send, and bus
out meters to either POST EQ or POST ON.
Option I/O Meters (input channels 17–24)
Signal level meters for input channels 17 through 24 and the Option I/O outputs are
displayed on the OPTION pages.
1. Use the [OPTION I/O] button to locate the OPTION pages.
Signal level meters for inputs 17 through 24 are displayed on OPTION page 1, as shown
below. The decibel value below each meter indicates the position of the corresponding
fader. The highlighted numbers 20 and 22 indicate that input channels 20 and 22 have
been swapped with input channels 4 and 6. See “Swapping Inputs 1–8 & 17–24” on
page 51 for more information.
Signal level meters for the Option I/O outputs are displayed on OPTION page 3, as
shown below. The source assigned to each output is displayed belo w its met er. These
assignments are made on OPTION page 4. See “ Assigning Option I/O Digital Outputs”
on page 219 for more information.