Zebra Technologies 7030 technical manual Status Reporting Commands

Models: 7030

1 128
Download 128 pages 16.1 Kb
Page 56
Image 56

56

Programming

Status Reporting Commands

Status Reporting Commands

See also Status Reporting on page 68.

Note • All status commands are immediate, that is they pass the print queue and is answered directly.

ESC ENQ 1

 

Status Enquiry

1B 05 01

hex

27 5 1

decimal

 

A status enquiry results in response ACK (06h) if all sensors are clear, but NAK (15h) + code if one or more sensors report fault condition.

 

 

 

Figure 19 • Error Codes

 

 

 

 

Error code

Meaning

 

 

 

 

ACK

OK (printer is operable)

 

 

 

 

NAK 1

Paper left in presenter module. Attempt to clear the paper path failed.*

 

 

 

 

NAK 2

Cutter jammed

 

 

 

 

NAK 3

Out of paper

 

 

 

 

NAK 4

Printhead lifted

 

 

 

 

NAK 5

Paper-feed error. No paper detected in presenter although 10 cm has been

 

 

printed. Paper might be wound around the platen or, in some way, has

 

 

been forced above the presenter module.

 

 

 

 

NAK 6

Temperature error. The printhead temperature has exceeded the 60 °C

 

 

maximum limit.

 

 

 

 

NAK 7

Presenter not running (no feedback from code wheel)

 

 

 

 

NAK 0A

Black mark not found

 

 

 

 

NAK 0B

Black mark calibration error

 

 

 

 

NAK 0C

Index error

 

 

 

 

NAK 0D

Checksum error

 

 

 

 

NAK 0E

Wrong firmware type

 

 

 

 

NAK 0F

Firmware cannot start because no firmware is loaded or firmware

 

 

checksum is wrong.

 

 

 

 

NAK 10

Waste bin timed out. If the customer doesn’t take the paper and the

 

 

printer clears the presenter due to a timeout, the pending error bit is set

 

 

and error code NAK 16 is reported.

 

 

 

 

NAK FF

Undefined error

 

 

 

 

 

 

 

 

*. From firmware version 3.00, the printer will retry three times (cut + clear presenter), when failing to clear the presenter.

P1003636-002

TTP 7030™ Technical Manual

10/05/2009

Page 56
Image 56
Zebra Technologies 7030 technical manual Status Reporting Commands