1.Enable black mark mode by setting parameters n35 to n42 as described on the previous pages.

2.Load paper with black marks into the printer.

3.Send the <ESC># command and wait until the paper stops.

4.If the paper has returned to it's original position, the calibration is finished.

5.If not, it was not possible to distinguish the black mark. Check the n37 and n38 settings and try again).

6.Save the settings with <ESC>&<4>.