Charging Battery Packs with the LI72
Plug the LI72 into the appropriate A.C. wall receptacle, then insert the charge cable into the battery pack charger jack.
The yellow/green charge indicator LED will indicate the sta- tus of the charger as per the following table.
Indicator |
| Charger |
| Charger Status |
| Function |
| ||
|
|
|
| |
Steady yellow indicator |
| Standby |
| AC power on; no battery |
|
| |||
|
|
|
| being charged |
|
|
|
| Charger is applying trickle |
|
|
|
| charge current (5% of |
Slow (1 Hz) flashing yellow |
|
| maximum) to bring a cold | |
indicator |
|
| battery temperature up to | |
|
|
| ||
|
|
|
| 0°C before starting a full |
|
|
|
| charge cycle |
Fast (4 Hz) flashing green |
|
|
| Charger is applying the |
| Rapid Charge |
| maximum charge rate to the | |
indicator |
|
| ||
|
|
| battery | |
|
|
|
| |
Slow (1 Hz) flashing green |
|
|
| Charger is in trickle charge |
| Maintain |
| mode(10% of nominal | |
indicator |
|
| ||
|
|
| charge value). | |
|
|
|
| |
|
|
|
| The battery may have an |
|
|
|
| internal short, or its charge |
Fast (4 Hz) flashing yellow |
| Error |
| monitoring circuitry may be |
indicator |
|
| malfunctioning. The battery | |
|
|
| ||
|
|
|
| pack should not be used any |
|
|
|
| further. |
Steady green indicator |
| Ready |
| No charge is being applied |
|
| to the battery | ||
|
|
|
| |
|
|
|
| Battery temperature is too |
Slow (1 Hz) flashing alternate |
| Wait |
| hot. Charging will not begin |
yellow and green indicator |
|
| until battery temperature | |
|
|
| ||
|
|
|
| reaches 45°C. |
|
|
|
|
|
Notes • Do not charge batteries with the
Charging will cease three (3) hours after the charger has entered the “Maintain” mode.
continued
15