Zebra Technologies RW 220, RW 420 manual Charging process per the following table

Models: RW 420 RW 220

1 86
Download 86 pages 12.14 Kb
Page 18
Image 18

the charging process per the following table:

UCLI72-4Battery Status Indicators

 

Amber LED

Green LED

Battery Status

 

 

 

 

 

 

 

On

Off

Charging

 

 

On

Flashing

80% charged (O.K. to use)

 

 

Off

On

Completely Charged

 

 

Flashing

Off

Fault

 

 

 

 

 

 

 

 

 

 

 

Important • A fault condition is caused by a problem with the battery. The charger may indicate a fault because the battery is too hot or too cold to charge reliably. Try to charge the battery again when it returns to the room’s ambient temperature. If the Amber indicator starts flashing on the second charging attempt, the battery should be discarded. Always dispose of batteries in a proper manner. Refer to Appendix E

LI72-4 Charger Cycle Times :

RW 420

RW 220

Battery 80% Charged

2.5 Hrs.

1.25 Hrs..

 

 

 

 

 

Battery Fully Charged

5 Hrs..

2.5 Hrs..

 

 

 

 

 

 

 

 

 

Note • Charge times are for completely discharged batteries.

Partially discharged Battery Packs will take less time than listed in the chart to reach a fully charged state. Once Battery Packs have reached 80% of their charge capacity they may be used, but it is recommended that you allow the batteries to reach a full charge to maintain maximum battery life.

Note • The UCLI72-4 Quad Charger’s safety features will stop the battery charging process after six hours regardless of the battery’s charge state.

18

RW Series User Guide

Page 18
Image 18
Zebra Technologies RW 220 Charging process per the following table, Battery 80% Charged Hrs 25 Hrs Battery Fully Charged