Charging Battery Packs with the LI72
Plug the LI72 into the appropriate AC wall receptacle, then insert the charge cable into the battery pack charger jack.
The amber/green charge indicator LED will indicate the sta- tus of the charger as per the following table.
|
| LED |
| Charger Status | ||||
|
| Status |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Green Solid | Fully Charged | |||||||
|
|
|
|
|
|
|
| |
Amber Solid | Charging | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| • | Battery Contact Problem | ||
| Amber |
| 1. Short Circuit of Output Terminals | |||||
Blinking |
| 2. Detection of Short Battery’s Circuit | ||||||
|
|
|
|
|
| 3. No Contact + Terminal | ||
|
|
|
|
| • | Over Voltage Protection | ||
|
|
|
|
| • | Over Current Protection | ||
|
|
|
|
| • | Temperature Waiting Time | ||
|
|
|
|
|
|
|
|
|
Operating Temperature | 0 to 40o C @ 30 to 85% Relative Humidity |
|
|
Storage Temperature | |
|
|
Input Voltage |
|
|
|
Input Current | 0.18A MAX |
|
|
Output | DC 8.4V 800mA |
|
|
16