Media and Ribbon Calibration
NOTE: All steps must be performed in the following procedure, even if only one sensor needs to be adjusted.
1.Press the SETUP/EXIT key.
2.Press the NEXT/SAVE key until “MEDIA AND RIBBON CALIBRATE” displays.
3.To start the calibration procedure, press the RIGHT BLACK OVAL key. “LOAD BACKING CANCEL CONTINUE” displays.
4.Open the printhead. Remove approximately 8” (203 mm) of labels from the media roll, enough so that only the backing material is threaded between the media sensors when the media is loaded (refer to Figure 11).
Remove
labels
Figure 11
Zebra | 17 |