Setting Communication Parameters

Communication parameters must be set correctly for the printer to communicate with the host. These parameters make sure that the printer and host are “speaking the same language.” All communications parameters are password protected.

 

Press

Display Shows

 

Action/Explanation

 

 

 

 

Setting Parallel Communications

Press the RIGHT or LEFT

 

 

 

 

BLACK OVAL key to display other choices.

 

 

 

PARALLEL

Default: Parallel

 

 

 

 

 

COMM

Selections: Parallel, twinax/coax

 

 

 

 

 

Select the communications port that matches the one being used

 

 

 

 

by the host computer.

 

 

 

 

 

 

 

 

 

 

 

Setting Serial Communications

Press the RIGHT or LEFT

 

 

 

 

BLACK OVAL key to display other choices.

 

 

 

SERIAL COMM

Default: RS232

 

 

 

 

 

Selections: RS232, RS422/485, RS485 multidrop

 

 

 

 

 

 

 

 

Select the communications port that matches the one being used

 

 

 

 

by the host computer.

 

 

 

 

 

 

 

 

 

 

 

Setting Baud

Press the RIGHT or LEFT BLACK OVAL key to

 

 

 

 

display other choices.

 

 

 

 

 

Default: 9600

 

 

 

 

 

BAUD

Selections: 110, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200,

 

 

 

28800, 38400, 57600

 

 

 

 

 

 

 

 

 

 

The baud setting of the printer must match the baud setting of

 

 

 

 

the host for accurate communications to take place. Select the

 

 

 

 

value that matches the one being used by the host.

 

 

 

 

 

 

 

 

 

 

Setting Data Bits

Press the RIGHT or LEFT BLACK OVAL key

 

 

 

 

to display other choices.

 

 

 

 

 

Default: 7-bits

 

 

 

 

 

DATA BITS

Selections: 7-bits, 8-bits

 

 

 

 

The data bits of the printer must match the data bits of the host

 

 

 

 

 

 

 

 

for accurate communications to take place. Set the data bits to

 

 

 

 

match the setting being used by the host.

 

 

 

 

NOTE: Must be set to 8 data bits to use Code Page 850.

 

 

 

 

 

 

 

 

Zebra XiIII-Series User’s Guide

53