Routine Care and Adjustment
CleaningThe following table provides a brief cleaning schedule. Specific cleaning procedures are provided on the following pages.
| Area | Method | Interval |
|
| Printhead | Solvent* |
|
|
|
|
| Direct thermal print mode: |
|
| Platen roller | Solvent* |
| |
|
|
| After every roll of media (or |
|
| Transmissive sensor | Air blow |
| |
| 500’/152 m of fanfold media). |
| ||
| Black mark sensor | Air blow | Thermal transfer print mode: |
|
|
|
|
| |
| Media path | Solvent* |
| |
| After every roll of ribbon. |
| ||
| Ribbon sensor | Air blow |
|
|
|
|
|
|
|
| Label available sensors | Air blow | Monthly |
|
|
|
|
|
|
| Solvent* |
|
| |
|
|
|
|
|
| Snap plate | Solvent* | As needed |
|
|
|
|
|
|
| Cutter | Solvent* |
|
|
|
|
|
|
|
* Zebra recommends using a solvent containing 90% isopropyl alcohol.
CAUTION: Use only the cleaning agents indicated. Zebra Technologies Corporation will not be responsible for any other fluids being used on this printer.
Zebra | 65 |