Press

Display Shows

Action/Explanation

 

 

 

 

Media and Ribbon Sensor Sensitivity Press NEXT/SAVE to skip

 

 

 

 

the calibration procedure and continue with the host port

 

 

 

 

selection parameters that follow. Press the RIGHT BLACK OVAL

 

 

 

MEDIA AND

key to start the calibration procedure.

 

 

 

 

 

 

 

RIBBON

This procedure is used to adjust the sensitivity of the media and

 

 

 

CALIBRATE

ribbon sensors.

 

 

 

 

NOTE: The procedure must be followed exactly as presented.

 

 

 

 

All steps must be performed even if only one of the

 

 

 

 

sensors requires adjustment.

 

 

 

 

 

 

 

Media and Ribbon Calibration Procedure

 

 

 

 

 

 

 

 

 

Press the LEFT BLACK OVAL key to cancel the operation, or do

 

 

 

 

the following:

 

 

 

LOAD BACKING

1) Open the printhead.

 

 

 

 

 

2)Remove approximately 8” (203 mm) of labels from the media roll, enough so that only the backing material is threaded between the media sensors when the media is loaded.

 

 

Press the LEFT BLACK OVAL key to cancel the operation or do

 

 

the following:

 

REMOVE RIBBON

1) Remove the ribbon (sliding it as far to the right as possible will

 

 

have the same effect as removing it).

 

 

2) Close the printhead.

 

 

 

 

 

The printer automatically adjusts the scale (gain) of the signals it

 

CALIBRATING

receives from the media and ribbon sensors based on the

 

specific media and ribbon combination you are using. On the

 

PLEASE WAIT

 

sensor profile, this essentially corresponds to moving the graph

 

 

 

 

up or down to optimize the readings for your application.

 

 

 

 

 

When “RELOAD ALL” is displayed:

 

 

1) Open the printhead and pull the media forward until a label is

----

RELOAD ALL

positioned under the media sensor.

2)Move the ribbon back to its proper position.

3)Close the printhead.

 

Now that the scale has changed, the printer performs a

 

calibration equivalent to pressing the CALIBRATE key. During

MEDIA AND

this process, the printer checks the readings for the media and

ribbon based on the new scale you have established, determines

RIBBON

the label length, and determines whether you are in direct

CALIBRATE

thermal or thermal transfer print mode. The process is now

 

 

complete! To see the new readings on the new scale, print a

 

sensor profile.