Porter-Cable D28733-034-0 Safety Guidelines / Definitions, Important Safety Instructions, Be used

Page 3

SAFETY GUIDELINES / DEFINITIONS

This manual contains information that is important for you to know and understand. This infor- mation relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections.

indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

indicates a potentially hazardous situation which, if not avoided,may result in minor or moderate injury

used without the safety alert symbol indicates potentially hazardous situation which, if not avoided, may result in property damage.

IMPORTANT SAFETY INSTRUCTIONS

Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and

operating instructions before using.

RISK OF ELECTROCUTION AND FIRE

HAZARD

WHAT CAN HAPPEN

HOW TO PREVENT IT

 

 

 

Attempting to

Back feeding electricity through

Never backfeed electricity

connect generator

a building’s electrical system to

through a structure's electrical

directly to the

the outside utility feed lines

system.

electrical system

could endanger repair persons

 

of any building

attempting to restore service.

 

structure.

 

 

Attempting to connect to the in-

To connect to a structure's electri-

 

 

coming utility service could result

cal system in a safe manner,

 

in electrocution.

always have a Double-Throw

 

 

Transfer Switch installed by a

 

Restoration of electrical service

qualified electrician and in compli-

 

while the generator is connected

ance with local ordinances.

 

to the incoming utility could

(When installing a Double-

 

result in a fire or serious damage

Throw Transfer Switch, a mini-

 

if an isolator switch is not

mum of 10 gauge wiring must

 

installed.

be used.)

 

Failure to use a double throw

 

 

transfer switch when connecting

 

 

to a structure's electrical system

 

 

can damage appliances and

 

 

WILL VOID the manufacturer's

 

 

warranty.

 

3- ENG

D28733

Image 3
Contents Generator Consumer Safety Information Consumer General and Service InformationRisk of Electrocution and Fire Safety Guidelines / DefinitionsImportant Safety Instructions When installing a DoubleGenerator in rain When damagedRisk of Electrocution and Fire OperationRisk of Fire Unit Indoors or in ANYConfined Area Risk of Unsafe Operation Risk of Breathing Inhalation HazardRisk of HOT Surfaces Specifications Risk of Moving PartsRisk from Lifting Extension Cord Wrap Forms and Protective BAR AssemblyRemove Generator from Carton Other Loose PartsHandle Rubber BumperExtension Cords Double Throw Transfer SwitchGrounding the Generator Obtaining Electricity from the GeneratorOperation To Start the Engine Stopping Engine Connecting Electrical LoadsCustomer Responsibilities Table MaintenanceEngine Maintenance Generator MaintenanceStorage Engine PreparationGenerator Wattage Calculations Determining Wattage RequirementsTotal Starting Wattage Requirements Application GuideAppliance or Load Device Typical Device Wattage Total Household Wattage CalculatorStart Troubleshooting GuideResponsibility of Original Purchaser initial User Limited WarrantyQuick Facts Modelo GeneradoresInformación General Y DE Servicio Pautas DE SEGURIDAD/DEFINICIONES Instrucciones Importantes DE SeguridadRiesgo ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? Generador bajo SubdimensionadosRiesgo DE Incendio Y Electrocución continuación Operación delEl motor está en Intentar llenar elTanque de com Bustible mientrasVehículo IncendioInhalación, daños a Las superficies delLas fluctuaciones Riesgo DE Operación Insegura continuaciónOperación de Equipos sensiblesTabla DE Especificaciones Colgador Para Cordón DE Extensión Y Barra Protectora InstalaciónSacar EL Generador DE LA Caja Otras Partes SueltasHandle Tope DE CauchoInterruptor DE Transferencia DE Doble Hoja Conexión a Tierra DEL GeneradorAbasteciéndose DE Electricidad DEL Generador Cables DE Extensión EléctricaDispositivo DE Apagado POR Poco Aceite Familiarizarse CON EL GeneradorCapacidad DEL Generador Interruptores DE CircuitoAntes de arrancar el generador Arranque Manual DEL MotorParando EL Motor Mantenimiento DEL Motor Programa DE MantenimientoCartilla DE Responsabilidades DEL Cliente Recomendaciones GeneralesAlmacenaje Preparación DEL MotorGenerador Importante Determinando LOS Requerimientos DE PotenciaVatios de Funcionamiento Volts X Ampers = Vatios Volts x 10 ampers = 1 200 W Potencia Requerida Para EL ArranqueCalculo DE Potencia Doméstica PrecaucionProblema Causa Corrección Guía Para Diagnóstico DE ProblemasResponsabilidad DEL Comprador Original Usuario inicial Garantía LimitadaInformacion Rapida Sobre Generadores Gasolina Para EL Motor Aceite Potencia Cableado Batería YMotor Almacenaje Operación Manuel Renseignements Pour LE Consommateur Mesures DE Sécurité Définitions Mesures DE Sécurité ImportantesRisques Délectrocution ET D’INCENDIE Risque Risques Délectrocution ET D’INCENDIE suiteRisques D’INCENDIE Risques D’UNE Utilisation Risques AUX Voies Respiratoires ET Risques D’INHALATIONRisques Reliés AUX Surfaces Chaudes Spécifications Risques Reliés AUX Pièces MobilesRisques Lors DU Levage Fonctionnement et de l’entretien du Guide de l’utilisateur Retrait DE LA Génératrice DE SON EmballageAutres Pièces Détachées Dévidoirs DE Rallonge ET Barre ProtectricePoignée PARE-CHOCS EN CaoutchoucInverseur Bidirectionnel Mise À LA Terre DE LA GénératriceComment Obtenir DE L’ÉLECTRICITÉ DE LA Génératrice RallongesCOUPE-CIRCUIT UtilisationBien Connaître Votre Génératrice Capacité DE LA GénératriceFaçon permanente les appareils branchés Démarrage DU MoteurArrêt DU Moteur Entretien DU Moteur Recommandations GénéralesEntretien Tableau DES Responsabilités DU ClientEntreposage Préparation DU MoteurGénératrice Puissance de service Calcul DE LA Puissance EN WattsDétermination DES Exigences DE Puissance EN Watts Volts x ampères = watts Volts x 10 ampères = 1 200 watts Puissance D’AMORÇAGE EN WattsCalcul DE LA Puissance EN Watts Mise EN GardeProblème Cause Correction Guide DE DépannageResponsabilité DE Lacheteur Dorigine utilisateur initial Garantie LimitéeRemarque 67- FR D28733 Toujours Consulter LES Guides Fournis Avec CET Appareil Faits Saillants

D28733-034-0, PGN350 specifications

The Porter-Cable D28733-034-0, PGN350 is a versatile and robust tool designed for professionals and DIY enthusiasts who demand high-performance tools in their projects. This pneumatic nail gun is engineered for reliability and precision, making it a popular choice in the construction and woodworking industries.

One of the main features of the PGN350 is its lightweight design, which enhances portability and ease of use. Weighing in at just a few pounds, operators can maneuver this tool comfortably for extended periods, reducing fatigue during long job sessions. Additionally, its durable construction ensures it can withstand the rigors of job site conditions.

Equipped with a powerful motor, the PGN350 delivers exceptional driving force, allowing it to effortlessly handle a range of fasteners, including 1-1/4 inch to 3-1/2 inch collated framing nails. This versatility makes it suitable for various applications, including framing, decking, and other structural tasks. The tool’s depth adjustment feature provides improved control over nail depth, ensuring a professional finish even on varying materials.

The PGN350 incorporates advanced technologies that enhance user experience and performance. Its rapid-fire mode allows for quick and efficient nailing, which is an essential feature for projects requiring high productivity. Moreover, the tool is designed with a tool-free jam release mechanism, making it easy to clear nail jams without the need for additional tools, thus minimizing downtime.

Safety is also a priority with the PGN350. It comes equipped with a trigger lock-off feature, which prevents accidental firing, offering peace of mind when the tool is not in use. This safety mechanism is fundamental for maintaining workplace safety, particularly in busy construction environments.

The unit features a comfortable grip and an ergonomic design that provides stability and control, reducing the risk of wrist strain and enhancing overall efficiency. The tool's air inlet is compatible with standard air hoses, making it easy to integrate into existing pneumatic tool systems.

In summary, the Porter-Cable D28733-034-0, PGN350 stands out for its lightweight design, powerful performance, and user-friendly features. Its advanced technologies, safety mechanisms, and versatility make it an essential tool for anyone looking to accomplish professional-grade results in their woodworking or construction projects. Whether you are framing a house or building furniture, the PGN350 is built to deliver reliability and precision every time.