Porter-Cable D28733-034-0, PGN350 Risk of Fire, Unit Indoors or in ANY, Confined Area

Page 5

RISK OF FIRE

HAZARD

WHAT CAN HAPPEN

HOW TO PREVENT IT

 

 

 

Attempting to

Gasoline and gasoline vapors

Turn engine off and allow it to

fill the fuel tank

can become ignited by coming

cool before adding fuel to the

while the engine

in contact with hot components

tank. Equip area of operation

is running.

such as the muffler, engine

with a fire extinguisher certified

 

exhaust gases, or from an

to handle gasoline or fuel fires.

 

electrical spark.

 

Sparks, fire, hot

Cigarettes, sparks, fires, or

Add fuel to tank in well

objects

other hot objects can cause

ventilated area. Make sure there

 

gasoline or gasoline vapors to

are no sources of ignition near

 

ignite.

the generator.

Improper storage

Improperly stored fuel could

Store fuel in a OSHA approved

of fuel

lead to accidental ignition. Fuel

container designed to hold

 

improperly secured could get

gasoline. Store container in se-

 

into the hands of children or

cure location to prevent use by

 

other unqualified persons.

others.

 

 

 

Inadequate

Materials placed against or near

Operate generator in a clean, dry,

ventilation for

the generator or operating the

well ventilated area a minimum of

generator

generator in areas where the

four feet from any building, object

 

temperature exceeds 104° F. am-

or wall. DO NOT OPERATE

 

bient (such as storage rooms or

UNIT INDOORS OR IN ANY

 

garages) can interfere with its

CONFINED AREA.

 

proper ventilation features caus-

 

 

ing overheating and possible ig-

 

 

nition of the materials or build-

 

 

ings.

 

Tampering with

Engine speed has been factory

Never attempt to “speed-up”

factory set

set to provide safe operation.

the engine to obtain more per-

engine speed

Tampering with the engine speed

formance. Both the output

settings.

adjustment could result in

voltage and frequency will be

 

overheating of attachments and

thrown out of standard by this

 

could cause a fire.

practice, endangering

 

 

attachments and the user.

 

 

 

Overfilling the fuel

Spilled fuel and its vapors can

Use care in filling the tank to

tank – fuel

become ignited from hot

avoid spilling fuel. Make sure

spillage.

surfaces or sparks.

fuel cap is secured tightly and

 

 

check engine for fuel leaks

 

 

before starting engine. Move

 

 

generator away from refueling

 

 

area or any spillage before

 

 

starting engine. Allow for fuel

 

 

expansion. Keep maximum fuel

 

 

level ¼ inch below the tip of the

 

 

fuel tank. Never refuel with the

 

 

engine running.

 

 

 

5- ENG

D28733

Image 5
Contents Generator Consumer Safety Information Consumer General and Service InformationImportant Safety Instructions Safety Guidelines / DefinitionsWhen installing a Double Risk of Electrocution and FireRisk of Electrocution and Fire When damagedOperation Generator in rainConfined Area Risk of FireUnit Indoors or in ANY Risk of Unsafe Operation Risk of Breathing Inhalation HazardRisk of HOT Surfaces Risk from Lifting SpecificationsRisk of Moving Parts Remove Generator from Carton AssemblyOther Loose Parts Extension Cord Wrap Forms and Protective BARHandle Rubber BumperGrounding the Generator Double Throw Transfer SwitchObtaining Electricity from the Generator Extension CordsOperation To Start the Engine Stopping Engine Connecting Electrical LoadsEngine Maintenance MaintenanceGenerator Maintenance Customer Responsibilities TableGenerator StorageEngine Preparation Total Wattage CalculationsDetermining Wattage Requirements Starting Wattage Requirements Application GuideAppliance or Load Device Typical Device Wattage Total Household Wattage CalculatorStart Troubleshooting GuideResponsibility of Original Purchaser initial User Limited WarrantyQuick Facts Modelo GeneradoresInformación General Y DE Servicio Riesgo ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? Pautas DE SEGURIDAD/DEFINICIONESInstrucciones Importantes DE Seguridad Riesgo DE Incendio Y Electrocución continuación SubdimensionadosOperación del Generador bajoTanque de com Intentar llenar elBustible mientras El motor está enInhalación, daños a IncendioLas superficies del VehículoOperación de Riesgo DE Operación Insegura continuaciónEquipos sensibles Las fluctuacionesTabla DE Especificaciones Sacar EL Generador DE LA Caja InstalaciónOtras Partes Sueltas Colgador Para Cordón DE Extensión Y Barra ProtectoraHandle Tope DE CauchoAbasteciéndose DE Electricidad DEL Generador Conexión a Tierra DEL GeneradorCables DE Extensión Eléctrica Interruptor DE Transferencia DE Doble HojaCapacidad DEL Generador Familiarizarse CON EL GeneradorInterruptores DE Circuito Dispositivo DE Apagado POR Poco AceiteAntes de arrancar el generador Arranque Manual DEL MotorParando EL Motor Cartilla DE Responsabilidades DEL Cliente Programa DE MantenimientoRecomendaciones Generales Mantenimiento DEL MotorGenerador AlmacenajePreparación DEL Motor Vatios de Funcionamiento ImportanteDeterminando LOS Requerimientos DE Potencia Volts X Ampers = Vatios Volts x 10 ampers = 1 200 W Potencia Requerida Para EL ArranqueCalculo DE Potencia Doméstica PrecaucionProblema Causa Corrección Guía Para Diagnóstico DE ProblemasResponsabilidad DEL Comprador Original Usuario inicial Garantía LimitadaMotor Almacenaje Operación Informacion Rapida Sobre GeneradoresGasolina Para EL Motor Aceite Potencia Cableado Batería Y Manuel Renseignements Pour LE Consommateur Risques Délectrocution ET D’INCENDIE Mesures DE Sécurité DéfinitionsMesures DE Sécurité Importantes Risque Risques Délectrocution ET D’INCENDIE suiteRisques D’INCENDIE Risques D’UNE Utilisation Risques AUX Voies Respiratoires ET Risques D’INHALATIONRisques Reliés AUX Surfaces Chaudes Risques Lors DU Levage SpécificationsRisques Reliés AUX Pièces Mobiles Autres Pièces Détachées Retrait DE LA Génératrice DE SON EmballageDévidoirs DE Rallonge ET Barre Protectrice Fonctionnement et de l’entretien du Guide de l’utilisateurPoignée PARE-CHOCS EN CaoutchoucComment Obtenir DE L’ÉLECTRICITÉ DE LA Génératrice Mise À LA Terre DE LA GénératriceRallonges Inverseur BidirectionnelBien Connaître Votre Génératrice UtilisationCapacité DE LA Génératrice COUPE-CIRCUITFaçon permanente les appareils branchés Démarrage DU MoteurArrêt DU Moteur Entretien Recommandations GénéralesTableau DES Responsabilités DU Client Entretien DU MoteurGénératrice EntreposagePréparation DU Moteur Détermination DES Exigences DE Puissance EN Watts Puissance de serviceCalcul DE LA Puissance EN Watts Volts x ampères = watts Volts x 10 ampères = 1 200 watts Puissance D’AMORÇAGE EN WattsCalcul DE LA Puissance EN Watts Mise EN GardeProblème Cause Correction Guide DE DépannageResponsabilité DE Lacheteur Dorigine utilisateur initial Garantie LimitéeRemarque 67- FR D28733 Toujours Consulter LES Guides Fournis Avec CET Appareil Faits Saillants

D28733-034-0, PGN350 specifications

The Porter-Cable D28733-034-0, PGN350 is a versatile and robust tool designed for professionals and DIY enthusiasts who demand high-performance tools in their projects. This pneumatic nail gun is engineered for reliability and precision, making it a popular choice in the construction and woodworking industries.

One of the main features of the PGN350 is its lightweight design, which enhances portability and ease of use. Weighing in at just a few pounds, operators can maneuver this tool comfortably for extended periods, reducing fatigue during long job sessions. Additionally, its durable construction ensures it can withstand the rigors of job site conditions.

Equipped with a powerful motor, the PGN350 delivers exceptional driving force, allowing it to effortlessly handle a range of fasteners, including 1-1/4 inch to 3-1/2 inch collated framing nails. This versatility makes it suitable for various applications, including framing, decking, and other structural tasks. The tool’s depth adjustment feature provides improved control over nail depth, ensuring a professional finish even on varying materials.

The PGN350 incorporates advanced technologies that enhance user experience and performance. Its rapid-fire mode allows for quick and efficient nailing, which is an essential feature for projects requiring high productivity. Moreover, the tool is designed with a tool-free jam release mechanism, making it easy to clear nail jams without the need for additional tools, thus minimizing downtime.

Safety is also a priority with the PGN350. It comes equipped with a trigger lock-off feature, which prevents accidental firing, offering peace of mind when the tool is not in use. This safety mechanism is fundamental for maintaining workplace safety, particularly in busy construction environments.

The unit features a comfortable grip and an ergonomic design that provides stability and control, reducing the risk of wrist strain and enhancing overall efficiency. The tool's air inlet is compatible with standard air hoses, making it easy to integrate into existing pneumatic tool systems.

In summary, the Porter-Cable D28733-034-0, PGN350 stands out for its lightweight design, powerful performance, and user-friendly features. Its advanced technologies, safety mechanisms, and versatility make it an essential tool for anyone looking to accomplish professional-grade results in their woodworking or construction projects. Whether you are framing a house or building furniture, the PGN350 is built to deliver reliability and precision every time.