American Dryer Corp ADG-60 service manual No Heat Condition Gas

Page 40

C. No Heat Condition (Gas)

1.Check to see if D.S.I. module fault indicator L.E.D. is red. If red, refer to ADC D.S.I. troubleshooting manual (P/N 450142).

2.Check for voltage across the "TH" and "GND" terminal of the module. If voltage is evident refer to ADC D.S.I. technical manual (P/N 450142).

NOTE: In the preceding steps, when checking the voltage leave one of your meter lead

to terminal block #7 or any good ground connection. Make sure sail switch damper is closing properly.

IMPORTANT: By no means should the sail switch be tampered with or bypassed when under normal drying conditions.

3.Check for voltage across both terminals of the sail switch. If voltage is evident on both terminals, check for bad wire or termination on the red wire that leaves the sail switch and passes through the gas valve train connector to the "TH" terminal on D.S.I. module. If voltage is evident on one terminal of the sail switch, replace the sail switch.

4.Check for voltage across both terminal of the burner hi-limit switch.

If voltage is evident on both terminals, check for bad wire or termination on the red wire from the burner hi-limit switch through the J19 connector (top tumbler) or the J20 (bottom tumbler) connector, to the sail switch.

If voltage is evident on one terminal of the burner hi-limit switch, replace this hi-limit switch.

5.Check for voltage across both terminals of the tumbler hi-limit switch. If voltage is evident on both terminals, check for bad wire or termination on the red wire from the tumbler hi-limit switch through the J19 connector (top tumbler) or the J20 (bottom tumbler) connector, to the burner hi-limit switch. If voltage is evident on one terminal replace the tumbler hi-limit switch.

36

Image 40
Contents VAC Phase Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Electrical Troubleshooting Cleaning SectionAdjustments LubricationTo Remove Lint Drawer To remove gas valve train assemblyTo remove control middle or lint lower door To Remove Control Box To Remove and Replace Lint Drawer Switch AssemblyTo Remove Front Panel To Remove and Replace Sensor Bracket and Components To Remove or Replace Belt Loctite To Remove or Replace Motor Reverse steps 1 through Loctite Belt and Idler Tension Adjustment To Remove or Replace Impellor FanFan Belt and Tension Adjustment To Replace Dual Control Microprocessor DMC ComputerTo Replace Touchpad Keypad To Replace Coin AcceptorTo Replace either Motor Relay Basket Tumbler Alignment VerticalBasket Tumbler Alignment Lateral To Replace Basket tumbler or Basket tumbler Support Loctite To Replace Basket tumbler Support Pillow Block Bearing Important Never strike the shaft directly with a hammerPage To Replace Basket Tumbler Support Flange Bearing To Replace 330º F Burner Hi-Limit Switch Thermostat To Replace Main Door Switch To Replace Sail SwitchTo Replace Direct Spark Ignition DSI Module AA. To Replace Ignitor and Probe BB. To Replace Gas ValveDiscontinue power to the dryer DD. To Replace Coin VaultFF. To Install New Main Door Glass EE. To Remove Main DoorGG. To Replace Main Door Gasket HH. To Replace Main Door HingeTroubleshooting No L.E.D. DisplayDMC computer L.E.D. display reads dSFL DMC computer L.E.D. display reads Hot DMC computer L.E.D. display reads SeflIf dryer is equipped with optional battery back up Dryer operates, but is taking to long to dry Condensation on main door glassDryer is making scraping noise at basket tumbler area Excessive noise or vibrationElectrical Troubleshooting No Display ConditionNo Start Condition Motor Doesnt Turn No Heat Condition Gas DOOr Condition DSFL Condition Technical Information Data LabelUsing a Manometer HOW to USE a ManometerE.D. Display Codes ClccFill Phase 5 System Diagnostics Diagnostic L.E.D. Display Failure CodesE.D. Display Indicators DOT Phase 5 DMC Computer Relay Output L.E.D. IndicatorsPhase 5 DMC Computer Input and Output L.E.D. Indicators WR ADC450162 1- 10/15/98-50