Generac 005735-0, 005734-0 owner manual To Start the Engine

Page 13

Operation

The manufacturer does not recommend using any gasoline containing alcohol (such as “gasohol”). If using any gasoline containing alcohol, it must not contain more than 10 percent ethanol, and

it must be removed from the generator during storage. Do NOT use any gasoline containing methanol. If using gasoline with alcohol, inspect more frequently for fuel leaks and other abnormalities.

2.8TO START THE ENGINE

Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on.

Unplug all electrical loads from the unit's receptacles before starting the engine.

Make sure the unit is in a level position.

Open the fuel shut-off valve (Figure 16).

Never operate in an enclosed area or indoors!

NEVER use in the home, or in partly enclosed areas such as garages, even if doors and windows are open! ONLY use outdoors and far from open windows, doors, vents, and in an area that will not accumulate deadly exhaust.

Figure 16 - Fuel Shut-off Valve

Locate the Idle Control ON/OFF switch on the control panel and set it to the “OFF” position (Figure 17).

Figure 17 - Idle Control Switch

Move engine CHOKE knob outward to “Full Choke” position (Figure 18).

Figure 18 - Full Choke Position

To start engine, press and hold the Start/Run/Stop switch in the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position.

When the engine starts, move choke knob to “1/2 Choke” position until the engine runs smoothly and then fully in to the “Run” position. If engine falters, move choke knob back out to “1/2 Choke” position until the engine runs smoothly and then to “Run” position.

NOTE:

If engine fires, but does not continue to run, move choke lever to “Full Choke” and repeat starting instructions.

IMPORTANT: Do not overload the generator. Also, do not overload individual panel receptacles. These outlets are protected against overload with push-to-reset-type circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker opens and electrical output to that receptacle is lost. Read “Don’t Overload the Generator” carefully.

11

Image 13
Contents NOT Intended for USE in Critical Life Support Applications GP Series Portable GeneratorTable of Contents Introduction Safety RulesRead this Manual Thoroughly IntroductionExhaust & Location Hazards Safety RulesFire Hazards Electrical Shock MAY ResultID Plate Standards IndexUnpacking AssemblyGeneral Information Handle Assembly Battery ConnectionOperation Know the GeneratorHourmeter Tracks hours of operation 1 120 VAC, 20 AMP, Duplex Receptacle Hourmeter2 120 VAC, 20 AMP, Gfci Receptacle 5 12 Volt DC, 10 AMP Receptacle 3 120 VAC, 30 AMP ReceptacleConnecting Electrical Loads HOW to USE the GeneratorWattage Reference Guide Grounding the GeneratorAdding Gasoline Adding Engine OILMove engine Choke knob outward to Full Choke position Figure To Start the EngineStopping the Engine Charging a BatteryAutomatic Idle Control LOW OIL Pressure Shutdown SystemMaintenance Schedule Performing Scheduled MaintenanceProduct Specifications MaintenanceService AIR Cleaner Clean Spark Arrestor Screen Adjusting Valve ClearanceTo adjust valve clearance To check valve clearanceGeneral Avoid spray from spark plug holes when cranking engineLong Term Storage Other Storage TipsTroubleshooting Troubleshooting GuidePage Page MANUFACTURER’S Warranty Coverage WarrantyOwners Warranty Responsibilities PartEmission Related Parts MAY Include the Following if Equipped Emission Control System WarrantyBOX 8 Waukesha, WI Generac Power SYSTEMS, INCPart No H0676 Rev. D 06/07/11 Manual del propietario Tabla de contenidos Guía de detección de problemas GarantíaMantenimiento Reglas DE Seguridad IntroducciónLEA Este Manual Completamente IntroducciónPeligros DEL Escape Y Ubicación Reglas de seguridadPeligros DE Incendio ResultadoPlaca de ID Índice DE EstándaresEnsamble DesempaqueInformación general Instale las cubiertas de los postes de batería incluidas Conexión DE LA BateríaOperación Conozca EL GeneradorReceptáculo Gfci DE 120 VAC, 20 AMP Medidor DE HorasReceptáculo DE 12 Volt DC, 10 AMP Receptáculo DE 120 VAC, 30 AMPConexión a Tierra DEL Generador Cómo Usar Este GeneradorConexión DE LAS Cargas Eléctricas Agregar Gasolina Agregar Aceite DE MotorAdvertencia Control DE Mínimo Arranque DEL MotorCarga DE LA Batería Detener EL MotorDescongelador Y Operación EN Clima Frío Arranque InicialPrograma DE Mantenimiento ProgramadoRecomendaciones Generales Cómo Realizar MantenimientoPara Limpiar EL Generador Mantenimiento DEL GeneradorMantenimiento DEL Motor Revisar EL Nivel DE AceiteChispas Servicio AL Limpiador DE AireAjuste DE LA Claridad DE LA Válvula Vástago de Otros Consejos Para AlmacenamientoRetire toda la gasolina del tanque de combustible Tanque DE CombustibleDetección de fallas Guía DE Detección DE ProblemasCobertura DE LA Garantía DEL Fabricante GarantíaResponsabilidades DEL Dueño EN LA Garantía ParteGarantía DEL Sistema DE Control DE Emisiones Parte No H0676 Rev. D 07/06/11 Programación DE GarantíaManuel dentretien Lire attentivement ce manuel Table des matièresFonctionnement Guide de dépannageRègles DE Sécurité Lire Attentivement CE ManuelRemarque NE PAS faire fonctionner le générateur sous la pluieRègles de sécurité DemplacementRisques Dincendie Plaque Didentification Index DES NormesMontage DéballageInformations générales Branchement DE LA Batterie Installer les couvercles des bornes de batterie inclusHoromètre Relève les heures de fonctionnement Bien Connaître LE GénérateurCordons ET Connecteurs HoromètrePrise 120 V C.A., 30 a FonctionnementMise À LA Terre DU Générateur Utilisation DU GénérateurAvant LE Démarrage DU Générateur Installer le générateur sur une surface de niveauAjout DE Lhuile DE Moteur Ajout DE LessenceSchéma 16 Soupape darrêt Démarrage DU MoteurChargement DE LA Batterie Arrêt DU Moteur12.1 Démarrage Initial 12.3 RedémarrageRecommandations Générales Programme DE MaintenanceEffectuer LE Programme Dentretien Caractéristiques Techniques DES ProduitsMaintenance DU Moteur Maintenance DU GénérateurNettoyage DU Générateur 4 Vérification DU Niveau DhuileNettoyage DE Lécran Pare Étincelles Entretien DU Filtre À AIRRéglage DU JEU DES Soupapes Stockage À Long Terme GénéralitésAutres Conseils DE Stockage Ne pas stocker lessence dune saison sur lautreDépannage Guide DE DépannageCouverture DE Garantie DU Fabricant GarantieResponsabilités DE Garantie DU Propriétaire 1ère partie2ème partie Garantie DU Système DE Contrôle DES EmissionsRéférence 0H0676 Rév. D 07/06/11 Programme DE Garantie

005735-0, 005734-0 specifications

Generac 005735-0 and 005734-0 are high-performance energy solutions designed for residential and light commercial use, offering reliable power backup in various situations. Each model boasts distinct features and technologies that set them apart in the energy market.

The Generac 005735-0 is a 22 kW air-cooled automatic standby generator, engineered to deliver robust performance in the face of power outages. It is especially prized for its advanced Quiet-Test mode, which allows the generator to run at a lower speed for a five- or twelve-minute test, significantly reducing noise levels during routine checks. This feature makes it an excellent choice for neighborhoods with noise restrictions.

Designed with durability in mind, the 005735-0 utilizes a corrosion-resistant aluminum enclosure, ensuring longevity even in harsh weather conditions. Equipped with Generac's G-Flex technology, this model can operate efficiently while providing a steady power supply to essential appliances and systems like HVAC, refrigerators, and lights.

On the other hand, the Generac 005734-0 model features similar specifications but may serve a different market need with slight variations in design. Often marketed for slightly lower power requirements, this model provides a dependable 18 kW output.

Both generators incorporate a robust mobile link monitoring capability, allowing users to check the status and statistics of their generator remotely via a smartphone app. This feature adds a layer of convenience and peace of mind, allowing homeowners to monitor their systems from anywhere.

In terms of installation, these models are straightforward to set up, compatible with existing natural gas or liquid propane systems. They are also supported by Generac's extensive network of authorized installers, making the purchasing and installation process seamless for consumers.

Furthermore, both models come with a five-year limited warranty, affirming Generac's confidence in their reliability and durability. With the ability to provide instant power restoration during outages, the Generac 005735-0 and 005734-0 are ideal options for those prioritizing convenience and peace of mind in their homes.

Overall, these generators embody Generac's commitment to quality, innovation, and user-friendly technology, making them trusted choices for backup power solutions.