Generac 005735-0, 005734-0 owner manual Emission Control System Warranty

Page 23

Warranty

EMISSION CONTROL SYSTEM WARRANTY

Emission Control System Warranty (ECS Warranty) for equipment using small spark-ignited engines:

(a)Applicability: This warranty shall apply to equipment that uses small off-road engines. The ECS Warranty period shall begin on the date the new equipment is purchased by/delivered to its original, end-use purchaser/owner and shall continue for the lesser of:

(1)The period of time specified in the Generac Limited Warranty enclosed herewith, but not less than 24 months, or

(2)For engines equipped with hour meters, a number of operating hours equal to half of the engine’s useful life. The useful life is specified on the Emissions Control Label on the engine.

(b)General Emissions Warranty Coverage: Generac warrants to the original, end-use purchaser/owner of the new engine or equipment and to each subsequent purchaser/owner that the ECS when installed was:

(1)Designed, built and equipped so as to conform with all applicable regulations; and

(2)Free from defects in materials and workmanship which cause the failure of a warranted part at any time during the ECS Warranty Period.

(c)The warranty on emissions-related parts will be interpreted as follows:

(1)Any warranted part that is not scheduled for replacement as required maintenance in the Owner's Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by Generac according to Subsection (4) below. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.

(2)Any warranted part that is scheduled only for regular inspection as specified in the Owner's Manual shall be warranted for the ECS Warranty Period. A statement in the Owner’s Manual to the effect of "repair or replace as necessary" shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.

(3)Any warranted part that is scheduled for replacement as required maintenance in the Owner's Manual shall be warranted for the period of time prior to first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by Generac according to Subsection (4) below. Any such emissions-related part repaired or replaced under the ECS warranty shall be warranted for the remainder of the period prior to the first scheduled replacement point for that part.

(4)Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a Generac Authorized Warranty Service Facility.

(5)Notwithstanding the provisions of subsection (4) above, warranty services or repairs must be provided at Generac Authorized Service Facilities.

(6)When the engine is inspected by a Generac Authorized Warranty Service Facility, the purchaser/owner shall not be held responsible for diagnostic costs if the repair is deemed warrantable.

(7)Throughout the ECS Warranty Period, Generac shall maintain a supply of warranted emission-related parts sufficient to meet the expected demand for such parts.

(8)Any Generac authorized and approved emission-related replacement parts may be used in the performance of any ECS Warranty maintenance or repairs and will be provided without charge to the purchaser/owner. Such use shall not reduce Generac ECS Warranty obligations.

(9)No modifications, other than those explicitly approved by Generac, may be made to the generator. Unapproved modifications void this ECS Warranty and shall be sufficient ground for disallowing an ECS Warranty claim.

(10)Generac shall not be held liable hereunder for failures of any non-authorized replacement parts, or failures of any authorized parts caused by the use of non-authorized replacement parts.

EMISSION RELATED PARTS MAY INCLUDE THE FOLLOWING (IF EQUIPPED):

1)

FUEL METERING SYSTEM

3)

IGNITION SYSTEM

 

A.

CARBURETOR AND INTERNAL PARTS

 

A.

SPARK PLUGS

 

B.

FUEL TANK/CAP

 

B.

IGNITION COILS/MODULE

 

C.

FUEL LINES

4)

AIR INJECTION SYSTEM

 

D.

EVAPORATIVE VENT LINES

 

A.

PULSE AIR VALVE

 

E.

REGULATOR (GASEOUS FUELS)

5)

EXHAUST SYSTEM

2)

AIR INDUCTION SYSTEM

 

A.

CATALYST

 

A.

INTAKE MANIFOLD

 

B.

EXHAUST MANIFOLD

 

B.

AIR FILTER

 

 

 

Part 2

Part No. 0J3335 Rev. A 12/10

21

Image 23
Contents NOT Intended for USE in Critical Life Support Applications GP Series Portable GeneratorTable of Contents Introduction Safety RulesIntroduction Read this Manual ThoroughlyElectrical Shock MAY Result Safety RulesExhaust & Location Hazards Fire HazardsID Plate Standards IndexGeneral Information AssemblyUnpacking Handle Assembly Battery ConnectionHourmeter Tracks hours of operation Know the GeneratorOperation 2 120 VAC, 20 AMP, Gfci Receptacle Hourmeter1 120 VAC, 20 AMP, Duplex Receptacle 5 12 Volt DC, 10 AMP Receptacle 3 120 VAC, 30 AMP ReceptacleGrounding the Generator HOW to USE the GeneratorConnecting Electrical Loads Wattage Reference GuideAdding Gasoline Adding Engine OILMove engine Choke knob outward to Full Choke position Figure To Start the EngineLOW OIL Pressure Shutdown System Charging a BatteryStopping the Engine Automatic Idle ControlMaintenance Performing Scheduled MaintenanceMaintenance Schedule Product SpecificationsService AIR Cleaner To check valve clearance Adjusting Valve ClearanceClean Spark Arrestor Screen To adjust valve clearanceOther Storage Tips Avoid spray from spark plug holes when cranking engineGeneral Long Term StorageTroubleshooting Troubleshooting GuidePage Page Part WarrantyMANUFACTURER’S Warranty Coverage Owners Warranty ResponsibilitiesEmission Related Parts MAY Include the Following if Equipped Emission Control System WarrantyPart No H0676 Rev. D 06/07/11 Generac Power SYSTEMS, INCBOX 8 Waukesha, WI Manual del propietario Mantenimiento Guía de detección de problemas GarantíaTabla de contenidos Introducción IntroducciónReglas DE Seguridad LEA Este Manual CompletamenteResultado Reglas de seguridadPeligros DEL Escape Y Ubicación Peligros DE IncendioPlaca de ID Índice DE EstándaresInformación general DesempaqueEnsamble Instale las cubiertas de los postes de batería incluidas Conexión DE LA BateríaOperación Conozca EL GeneradorReceptáculo Gfci DE 120 VAC, 20 AMP Medidor DE HorasReceptáculo DE 12 Volt DC, 10 AMP Receptáculo DE 120 VAC, 30 AMPConexión DE LAS Cargas Eléctricas Cómo Usar Este GeneradorConexión a Tierra DEL Generador Advertencia Agregar Aceite DE MotorAgregar Gasolina Control DE Mínimo Arranque DEL MotorArranque Inicial Detener EL MotorCarga DE LA Batería Descongelador Y Operación EN Clima FríoCómo Realizar Mantenimiento ProgramadoPrograma DE Mantenimiento Recomendaciones GeneralesRevisar EL Nivel DE Aceite Mantenimiento DEL GeneradorPara Limpiar EL Generador Mantenimiento DEL MotorAjuste DE LA Claridad DE LA Válvula Servicio AL Limpiador DE AireChispas Tanque DE Combustible Otros Consejos Para AlmacenamientoVástago de Retire toda la gasolina del tanque de combustibleDetección de fallas Guía DE Detección DE ProblemasParte GarantíaCobertura DE LA Garantía DEL Fabricante Responsabilidades DEL Dueño EN LA GarantíaGarantía DEL Sistema DE Control DE Emisiones Parte No H0676 Rev. D 07/06/11 Programación DE GarantíaManuel dentretien Guide de dépannage Table des matièresLire attentivement ce manuel FonctionnementNE PAS faire fonctionner le générateur sous la pluie Lire Attentivement CE ManuelRègles DE Sécurité RemarqueRisques Dincendie DemplacementRègles de sécurité Plaque Didentification Index DES NormesInformations générales DéballageMontage Branchement DE LA Batterie Installer les couvercles des bornes de batterie inclusHoromètre Relève les heures de fonctionnement Bien Connaître LE GénérateurCordons ET Connecteurs HoromètrePrise 120 V C.A., 30 a FonctionnementMise À LA Terre DU Générateur Utilisation DU GénérateurAjout DE Lessence Installer le générateur sur une surface de niveauAvant LE Démarrage DU Générateur Ajout DE Lhuile DE MoteurSchéma 16 Soupape darrêt Démarrage DU Moteur12.3 Redémarrage Arrêt DU MoteurChargement DE LA Batterie 12.1 Démarrage InitialCaractéristiques Techniques DES Produits Programme DE MaintenanceRecommandations Générales Effectuer LE Programme Dentretien4 Vérification DU Niveau Dhuile Maintenance DU GénérateurMaintenance DU Moteur Nettoyage DU GénérateurRéglage DU JEU DES Soupapes Entretien DU Filtre À AIRNettoyage DE Lécran Pare Étincelles Ne pas stocker lessence dune saison sur lautre GénéralitésStockage À Long Terme Autres Conseils DE StockageDépannage Guide DE Dépannage1ère partie GarantieCouverture DE Garantie DU Fabricant Responsabilités DE Garantie DU Propriétaire2ème partie Garantie DU Système DE Contrôle DES EmissionsRéférence 0H0676 Rév. D 07/06/11 Programme DE Garantie

005735-0, 005734-0 specifications

Generac 005735-0 and 005734-0 are high-performance energy solutions designed for residential and light commercial use, offering reliable power backup in various situations. Each model boasts distinct features and technologies that set them apart in the energy market.

The Generac 005735-0 is a 22 kW air-cooled automatic standby generator, engineered to deliver robust performance in the face of power outages. It is especially prized for its advanced Quiet-Test mode, which allows the generator to run at a lower speed for a five- or twelve-minute test, significantly reducing noise levels during routine checks. This feature makes it an excellent choice for neighborhoods with noise restrictions.

Designed with durability in mind, the 005735-0 utilizes a corrosion-resistant aluminum enclosure, ensuring longevity even in harsh weather conditions. Equipped with Generac's G-Flex technology, this model can operate efficiently while providing a steady power supply to essential appliances and systems like HVAC, refrigerators, and lights.

On the other hand, the Generac 005734-0 model features similar specifications but may serve a different market need with slight variations in design. Often marketed for slightly lower power requirements, this model provides a dependable 18 kW output.

Both generators incorporate a robust mobile link monitoring capability, allowing users to check the status and statistics of their generator remotely via a smartphone app. This feature adds a layer of convenience and peace of mind, allowing homeowners to monitor their systems from anywhere.

In terms of installation, these models are straightforward to set up, compatible with existing natural gas or liquid propane systems. They are also supported by Generac's extensive network of authorized installers, making the purchasing and installation process seamless for consumers.

Furthermore, both models come with a five-year limited warranty, affirming Generac's confidence in their reliability and durability. With the ability to provide instant power restoration during outages, the Generac 005735-0 and 005734-0 are ideal options for those prioritizing convenience and peace of mind in their homes.

Overall, these generators embody Generac's commitment to quality, innovation, and user-friendly technology, making them trusted choices for backup power solutions.