Generac 004614-1 owner manual Obligations and Rights of the Manufacturer and Owner, Limitations

Page 67

Appendix 5 – Warranty

QUIETPACT™ 65D Recreational Vehicle Generator

OBLIGATIONS AND RIGHTS OF THE MANUFACTURER AND OWNER

The new model year, class of diesel engine, and emission application determination for your engine are identified on the emission control information label affixed to the right-hand side of your engine's timing gear case. The warranty period begins on the date the new equipment is sold to the first retail purchaser.

Any emission control system parts scheduled for regular inspection that are proven defective during normal use will be repaired or replaced during the warranty period. Any warranted part that is scheduled for replacement, and that fails prior to replacement, will be repaired or replaced under warranty, and the repaired or replaced part will be covered under war- ranty for the remainder of the period prior to the first scheduled replacement. The warranty repairs and service will be per- formed by any Generac Authorized Warranty Service Facility, with no charge for parts or labor (including diagnosis).

As the engine owner, you are responsible to perform all the required maintenance listed in your Owner's Manual. GEN- ERAC will not deny an emission warranty claim solely because you have no record of maintenance; however, a claim may be denied if your failure to perform maintenance resulted in the failure of a warranted part. Receipts covering reg- ular maintenance should be retained in the event of questions, and these receipts should be passed on to each subse- quent owner of the engine.

It is recommended that replacement parts used for maintenance or repairs be GENERAC authorized and approved parts, to maintain the quality originally designed into your emission-certified engine. However, any replacement part may be used in the performance of any warranty maintenance or repairs and must be provided without charge to the owner. Such use will not reduce the warranty obligations of GENERAC. Add-on or modified parts may not be used for maintenance or war- ranty repairs. Such use will be grounds for disallowing a warranty claim, and GENERAC will not be liable to warrant fail- ures of warranted parts caused by the use of an add-on or modified part.

LIMITATIONS

This warranty shall not cover any of the following:

(a)Systems and parts that were not first installed on the new equipment or engine as original equipment by GENERAC.

(b)Conditions resulting from tampering, misuse, abuse, improper adjustment, engine alteration, use of add-on or modified parts, use of replacement parts that are not the same in performance and durability as GENERAC-approved replacement parts, accident, failure to use the recommended fuel or oil, use of unapproved fuel or oil additives, or failure to perform required maintenance.

(c)Replacement parts used for required or scheduled maintenance.

(d)Consequential damages, such as, loss of time, inconvenience, or loss of use of this engine or equipment.

(e)Damages or repair costs caused by the owner's unreasonable delay in making the engine available for inspection and repair.

(f)Diagnosis or inspection fees that do not result in eligible warranty service being performed.

(g)Equipment with an altered or disconnected hourmeter, where the hours cannot be determined.

(h)Equipment normally operated outside the United States.

(i)Accident-caused damage, acts of nature, or other events beyond GENERAC’S control.

(j)Warranty repairs undertaken or attempted by the owner or any other person who is not affiliated with a Generac Authorized Warranty Service Facility.

OBTAINING WARRANTY SERVICE

To obtain service under this warranty, promptly contact your nearest Generac Authorized Service Dealer or a Generac Authorized Warranty Service Facility. If available, provide the GENERAC representative with the original purchase receipt (showing the initial date of purchase) and all available maintenance records.

Page 2

Generac® Power Systems, Inc. 65

Image 67
Contents Power SYSTEMS, INC Introduction Authorized Service Dealer LocationPart II Installation Instructions General Hazards Electrical Hazards Quietpact 65D Generator IdentificationGenerator AC Connection System SafetySpecifications Generator ApplicabilityEngine OIL Requirements Fuel Consumption GAL/HRGenerator Optional Remote START/STOP Generator Control PanelBefore Starting the Engine Starting the Generator Protection Systems Stopping the Generator1 25-HOUR BREAK-IN Period Additional InformationOverspeed Shutdown Overvoltage ProtectionEffects of Moisture and Dirt Checking the Engine OIL LevelChanging the Engine OIL AND/OR OIL Filter Operation in High Grass or BrushSpark Arrestor Muffler Servicing the Engine AIR FilterBattery Maintenance Cleaning the GeneratorDrive Belt OUT-OF-SERVICE ProcedureCooling System Engine CoolantReturn to Service SYSTEM/COMPONENT Procedure Frequency Service SchedulePart General Hazards Electrical Hazards Generator Engine Operating Speed Purpose and Scope ManualStandards Booklets Equipment DescriptionMajor Features and Dimensions Suspended Mounting Location and SupportGenerator Location Generator SupportGenerator Restraint Generator CompartmentsCompartment Construction Acoustics Sound Insulating MaterialsTypical Noise Abatement Compartment Floor CutoutsCooling AIR Inlet Openings Cooling and Ventilating AIRGenerator Airflow Diesel Fuel System Testing the InstallationCompensating for Restrictions Generator Fuel Return Lines Generator Fuel Supply LinesExhaust System Exhaust System SafetyMuffler and Spark Arrestor Electrical Junction BOX Electrical ConnectionsGenerator AC Connections Ground Fault Circuit Interrupters Power Supply CordIsolating Different Power Sources Battery Cable Connections Battery InstallationBattery Cables Recommended BatteryBattery Compartment Optional AccessoriesInitial Start Post Installation TestsTesting Under Load Before Initial StartupInstallation Checklist Problem Cause Correction Troubleshooting GuideAppendix 2 Electrical Data Appendix 2 Electrical Data Appendix 2 Electrical Data Appendix 3 Exploded Views and Parts Lists QTY Description Base Frame Weldment 174 Appendix 3 Exploded Views and Parts Lists Cooling System Drawing No. D2360 1926 Exhaust Gasket Description QTY Start / Stop Switch Camshaft Assembly Complete Cylinder Block Cylinder Head Assembly Crankshaft Assembly Part NO. QTY Description Rocker ARM Shaft Injector Pump Assembly Fuel Filter Support Appendix 3 Exploded Views and Parts Lists HOUSING, Timing Gear 3114 Water Pump Assembly Appendix 4 Notes Appendix 4 Notes Parts Covered Federal and California Emissions Control Warranty StatementYour Warranty Rights and Obligations Manufacturers Warranty CoverageObligations and Rights of the Manufacturer and Owner Obtaining Warranty ServiceLimitations Generac Power SYSTEMS, INC