KNOW YOUR GENERATOR

KNOW YOUR GENERATOR

Read this Operator’s Manual and safety rules before operating your generator.

Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

Oil Fill Cap

Air Cleaner

Spark Arrester Muffler

Battery

12 Volt DC Receptacle — Use this receptacle with

battery charge cables to charge a 12 Volt battery.

120 Volt AC, 20 Amp Duplex Receptacles — May be

used to supply electrical power for the operation of 120Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

120/240 Volt AC, 30 Amp Locking Receptacle — May

be used to supply electrical power for the operation of

120and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

Air Cleaner — Protects engine by filtering dust and debris out of intake air.

Battery — Located behind plastic cover. 12 Volt DC sealed battery provides power to start the engine.

Choke Lever — Used when starting a cold engine.

Fuel Tank

Rocker Switch Circuit

Breaker

 

 

Circuit Breakers (AC)

 

120 Volt AC, 20 Amp

 

Duplex Receptacles

 

120/240 Volt AC, 30 Amp

 

Locking Receptacle

 

Choke Lever

Data Tag

12 Volt DC

Receptacle

Start Switch

Grounding

Fastener

Circuit Breakers (AC) — The 120 Volt AC, 20A duplex receptacles are provided with "push to reset" circuit breakers to protect the generator against electrical overload.

Data Tag – Provides model, revision and serial number of generator. Please have these readily available if calling for assistance.

Fuel Tank — Capacity of seven (7) U.S. gallons. Start Switch — Turn to start the engine.

Grounding Fastener — If required, please consult a qualified electrician, electrical inspector, or local agency having jurisdiction.

Oil Fill Cap — Add oil to engine here.

Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.

Rocker Switch Circuit Breaker — The 120/240 Volt AC, 30A locking receptacle is provided with a rocker switch circuit breaker to protect the generator against electrical overload. This switch also controls all receptacles.

5

Image 5
Contents 01894-1 7000W Equipment Description Table of ContentsSafety Rules When Starting Equipment When Adding or Draining FuelWhen Operating Equipment When Transporting or Repairing EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorVolt AC, 20 Amp Duplex Receptacles May be Know Your Generator120/240 Volt AC, 30 Amp Locking Receptacle May 120/240 Volt AC, 30 AmpAttach Handle AssemblyUnpacking the Generator When Adding Fuel Remove Cover on Start SwitchBefore Starting the Engine Add Engine OilConnecting to a Building’s Electrical System Using the GeneratorSystem Ground Generator LocationStarting the Engine Jump Start ProcedureOperating Generator Charging a Battery Connecting Electrical LoadsStopping the Engine Do not Overload GENERATOR. See Don’t Overload GeneratorCold Weather Operation How to Use the Battery ChargerCreating a Permanent Cold Weather Shelter Creating a Temporary Cold Weather Shelter120/240 Volt AC, 30 Amp, Locking Receptacle ReceptaclesVolt AC, 20 Amp, Duplex Receptacle Volt DC, 10 Amp ReceptacleDON’T Overload Generator Power ManagementCapacity ExampleEngine Maintenance SpecificationsGeneral Maintenance Recommendations Storage Problem Cause Correction TroubleshootingPage Limited Warranty Table DES Matières Symboles de Danger et MoyensDescription DE L Équipement Règles DE SécuritéLors DU Démarrage DE Léquipement Lors DE Lajout OU DE LA Vidange DU CarburantLorsque Léquipement Fonctionne Lorsque Vous Transportez OU Réparez LéquipementLors DE Tests Dallumage DU Moteur Lorsque Vous Réglez OU Réparez Votre GénérateurConnaissez Votre Générateur Fixer la poignée AssemblageEnlever le génératrice de la boite Ajoutez de lhuile à moteur Avant LE Démarrage DU MoteurAjoutez de lessence Enlevez le couvercle de linterrupteur de démarrageUtilisation DE LA Génératrice Emplacement de la GénératriceMise à la terre du système Branchement au système électrique dun édificeProcédure de démarrage à laide dune batterie dappoint Utilisation DU GénérateurDémarrage du Moteur Arrêt du Moteur Branchement des Charges ÉlectriquesRecharge d’une Batterie Placez linterrupteur de démarrage à la position StopComment Utiliser le Chargeur de Batterie Fonctionnement PAR Temps FroidVent Création d’un abri temporaireCréation d’un abri permanent Prise à Verrouillage de 120/240 Volts c.a., 30 Ampères Prises DE CourantVolts c.a., 20 Ampères Prise de Courant Double Prise de 10 Ampères, 12 Volts c.cCapacité NE PAS Surcharger GénérateurGestion de la Consommation ExempleEntretien du Moteur Recommandations Générales D’ENTRETIENSpécifications Remisage Remarques Dépannage Garantie Limitée Période DE GarantieDescripción DEL Equipo Tabla DE ContenidosReglas DE Seguridad AdvertenciaCuando Añada Combustible O Vacíe EL Depósito PeligroCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Pruebe LA Bujía DEL Motor PrecauciónCuando Ajuste O Haga Reparaciones a SU Generador Placa de Características Conozca SU GeneradorAceite Llena la Tapa Agrega aceite al motor aquí Culatazo el Principio Usó para comenzar motorFije el Asa MontajeDesembalaje del Generador Agregar Aceite al Motor Antes DE Darle Arranque AL MotorAgregue Combustible Quite la Cubierta en el Interruptor del ArranqueTierra del Sistema USO DEL GeneradorUbicación del Generador Conexión al Sistema Eléctrico de un EdificioProcedimiento de Arranque en Puente Operando EL GeneradorEncienda el Motor Parado Del Motor Conexion De Cargas ElectricasCarga de la Bateria No Sobrecargue GENERADOR. Vea No Sobrecargue GeneradorCómo al Uso el Corcel de Batería Operación Durante UNClima Frío Figura 42 Refugio Frío Permanente del Tiempo 120/240 Voltios AC, 30 Amperios, Receptáculo de Seguridad Receptáculos PrecauciónVolt AC, 20 Amperios, Receptáculos Dobles Tomacorrientes de 12 Voltios DCCapacidad No Sobrecargue GeneradorControl de la Energía EjemploMantenimiento del Motor EspecificacionesRecomendaciones Generales DE Mantenimiento Almacenamiento Diagnositicos DE Averías Problemo Causa AccionNotas Notas Uso comercial Uso del consumidor