SPECIFICATIONS & MAINTENANCE

SPECIFICATIONS

Starting Wattage

12,250 Watts

Wattage

7,000 Watts

AC Load Current

 

At 120 Volts

. 58.3 Amps

At 240 Volts

. 29.1 Amps

Phase

. . . 1-phase

Rated Frequency

. . 60 Hertz

Fuel Tank Capacity

7 U.S. gallons

Shipping Weight

. . . 230 lbs.

GENERAL MAINTENANCE RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a

damaged or defective generator.

NOTE: If equipped with inflatable tires, keep the air pressure at the value marked on the tire or within 15 and 40 psi.

NOTE: Should you have questions about replacing components on your BSPP generator, please call 1-800-743-4115for assistance.

Engine Maintenance

See engine operator’s manual for instructions.

An oil drain tray is provided for your convenience to change the oil and oil filter. Store tray in a convenient location for periodic maintenance.

Changing Oil

1.Place the half moon notch in the oil drain tray under the oil drain plug (Figure 15).

Figure 15 — Changing Oil With Oil Drain Tray

drain tray notch

drain tray foot

2.Place the oil drain tray foot tab in the slot on the base of the generator, as shown.

3.Follow the instructions given in the engine operator’s manual for draining oil.

4.After oil has drained, reinstall the oil drain plug.

5.Remove the oil drain tray from under the oil drain plug and clean up any spilled oil.

Changing Oil Filter

1.Place the half moon notch in the oil drain tray under the oil filter (Figure 16).

Figure 16 — Changing Oil Filter With Oil Drain Tray

drain tray

notch

drain tray foot

2.Place the oil drain tray foot tab in the slot on the base of the generator, as shown.

3.Follow the instructions given in the engine operator’s manual for changing oil filter and adding oil.

4.Remove the oil drain tray from under the oil filter and clean up any spilled oil.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

15

Image 15
Contents 01894-1 7000W Table of Contents Safety RulesEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your Generator120/240 Volt AC, 30 Amp Know Your GeneratorVolt AC, 20 Amp Duplex Receptacles May be 120/240 Volt AC, 30 Amp Locking Receptacle MayAssembly Unpacking the GeneratorAttach Handle Add Engine Oil Remove Cover on Start SwitchWhen Adding Fuel Before Starting the EngineGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundJump Start Procedure Operating GeneratorStarting the Engine Do not Overload GENERATOR. See Don’t Overload Generator Connecting Electrical LoadsCharging a Battery Stopping the EngineCold Weather Operation How to Use the Battery ChargerCreating a Permanent Cold Weather Shelter Creating a Temporary Cold Weather ShelterVolt DC, 10 Amp Receptacle Receptacles120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptacleExample Power ManagementDON’T Overload Generator CapacitySpecifications General Maintenance RecommendationsEngine Maintenance Storage Problem Cause Correction TroubleshootingPage Limited Warranty Règles DE Sécurité Symboles de Danger et MoyensTable DES Matières Description DE L ÉquipementLorsque Vous Transportez OU Réparez Léquipement Lors DE Lajout OU DE LA Vidange DU CarburantLors DU Démarrage DE Léquipement Lorsque Léquipement FonctionneLors DE Tests Dallumage DU Moteur Lorsque Vous Réglez OU Réparez Votre GénérateurConnaissez Votre Générateur Assemblage Enlever le génératrice de la boiteFixer la poignée Enlevez le couvercle de linterrupteur de démarrage Avant LE Démarrage DU MoteurAjoutez de lhuile à moteur Ajoutez de lessenceBranchement au système électrique dun édifice Emplacement de la GénératriceUtilisation DE LA Génératrice Mise à la terre du systèmeUtilisation DU Générateur Démarrage du MoteurProcédure de démarrage à laide dune batterie dappoint Placez linterrupteur de démarrage à la position Stop Branchement des Charges ÉlectriquesArrêt du Moteur Recharge d’une BatterieComment Utiliser le Chargeur de Batterie Fonctionnement PAR Temps FroidCréation d’un abri temporaire Création d’un abri permanentVent Prise de 10 Ampères, 12 Volts c.c Prises DE CourantPrise à Verrouillage de 120/240 Volts c.a., 30 Ampères Volts c.a., 20 Ampères Prise de Courant DoubleExemple NE PAS Surcharger GénérateurCapacité Gestion de la ConsommationRecommandations Générales D’ENTRETIEN SpécificationsEntretien du Moteur Remisage Remarques Dépannage Garantie Limitée Période DE GarantieAdvertencia Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Opere EL Equipo PeligroCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Culatazo el Principio Usó para comenzar motor Conozca SU GeneradorPlaca de Características Aceite Llena la Tapa Agrega aceite al motor aquíMontaje Desembalaje del GeneradorFije el Asa Quite la Cubierta en el Interruptor del Arranque Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorOperando EL Generador Encienda el MotorProcedimiento de Arranque en Puente No Sobrecargue GENERADOR. Vea No Sobrecargue Generador Conexion De Cargas ElectricasParado Del Motor Carga de la BateriaOperación Durante UN Clima FríoCómo al Uso el Corcel de Batería Figura 42 Refugio Frío Permanente del Tiempo Tomacorrientes de 12 Voltios DC Receptáculos Precaución120/240 Voltios AC, 30 Amperios, Receptáculo de Seguridad Volt AC, 20 Amperios, Receptáculos DoblesEjemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaEspecificaciones Recomendaciones Generales DE MantenimientoMantenimiento del Motor Almacenamiento Diagnositicos DE Averías Problemo Causa AccionNotas Notas Uso comercial Uso del consumidor