Cisco Systems ONS 15600 SDH manual 18-68

Page 68

Chapter 18 DLPs F300 to F399

DLP- F355 Roll Two Cross-Connects from One Optical Circuit to a Second Optical Circuit

DLP-F355 Roll Two Cross-Connects from One Optical Circuit to a Second Optical Circuit

 

Purpose

This task reroutes a network path using two optical circuits by allowing

 

 

CTC to select the Roll To path on the second circuit automatically.

 

Tools/Equipment

None

 

Prerequisite Procedures

DLP-F181 Log into CTC, page 16-34

 

Required/As Needed

As needed

 

Onsite/Remote

Onsite or remote

 

Security Level

Provisioning and higher

 

 

Step 1

From the View menu, choose Go To Network View.

Step 2

Click the Circuits tab.

 

Step 3

Press Ctrl and click the two circuits that you want to use in the roll process.

 

The Roll From path will be on one circuit and the Roll To path will be on the other circuit. The circuits

 

must have a DISCOVERED status and must be the same size and direction for you to start a roll. The

 

planned Roll To circuit must not carry traffic.The first Roll To path must be DCC connected to the source

 

node of the Roll To circuit, and the second Roll To path must be DCC connected to the destination node

 

of the Roll To circuit.

 

Step 4

From the Tools menu, choose Circuits > Roll Circuit.

Step 5

In the Roll Attributes area, complete the following:

a.From the Circuit Roll Mode drop-down list, choose Auto to create an automatic roll (required for a 1-way source roll) or Manual to create a manual roll (required for 1-way destination roll).

b.From the Circuit Roll Type drop-down list, choose Dual.

c.In the Roll From Circuit area, click the circuit that contains the Roll From path.

Step 6 Click Next.

Step 7 In the Pivot/Fixed Point 1 window, click the square representing the fixed path of the first cross-connect to be rolled (Figure 18-13 on page 18-58).

This path is a fixed point in the cross-connect involved in the roll process. The path identifier appears in the text box below the graphic image. The path that is not selected contains the Roll From path. The Roll From path is deleted after the roll is completed.

Step 8 Click Next.

Step 9 Complete one of the following:

If multiple Roll From paths exist, the Select Roll From dialog box appears. Select the path from which you want to roll traffic and click OK (Figure 18-18 on page 18-64).

If multiple Roll From paths do not exist, continue with Step 10.

The circuit status for the Roll From path changes from DISCOVERED to ROLL PENDING.

Step 10 In the Pivot/Fixed Point 2 window, click the square that represents the fixed path of the second connection to be rolled.

The path that is not selected is the Roll From path. The Roll From path is deleted after the roll is completed. The path identifier appears in the text box below the graphic image.

 

Cisco ONS 15600 SDH Procedure Guide, R8.0

18-68

October 2007

Image 68
Contents DLP-F300 Install Fiber-Optic Cables for Sncp Configurations 18-1DLP-F302 Change Tunnel Type 18-218-3 DLP-F303 Delete Overhead CircuitsClick the Provisioning Overhead Circuits tabs DLP-F304 Repair an IP Tunnel 18-4J1 Function Cards 18-518-6 Selecting the Edit Path Trace Option18-7 18-8 DLP-F306 Provision Path Trace on STM-N PortsClick Circuits DLP-F307 Create Login Node Groups Click the Login Node Group tabClick Create Group 18-9Tools 18-10DLP-F310 Change the JRE Version 18-11DLP-F311 Remove Pass-through Connections 18-1218-13 DLP-F312 Delete a Node from a Specified Login Node GroupDLP-F313 Change a Circuit Service State DLP-F314 Provision MS-DCC Terminations 18-14Node view, click the Provisioning Comm Channels MS-DCC tabs 18-1518-16 DLP-F315 Provision a Proxy TunnelClick the Provisioning Network Proxy subtabs 18-17 DLP-F316 Provision a Firewall TunnelClick the Provisioning Network Firewall subtabs 18-18 DLP-F317 Delete a Proxy TunnelDLP-F318 Delete a Firewall Tunnel DLP-F319 Change an RS-DCC Termination DLP-F320 Change an MS-DCC TerminationClick the Provisioning Comm Channels RS-DCC tabs Click the Provisioning Comm Channels MS-DCC tabsDLP-F321 Delete an RS-DCC Termination DLP-F322 Delete an MS-DCC TerminationNode view, click the Provisioning Comm Channel RS-DCC tabs 18-20Click the Provisioning Comm Channel MS-DCC tabs 18-2118-22 DLP-F324 Provision Asap Ethernet PortsClick the Provisioning Ethernet Ports tabs DLP-F325 Provision Asap POS Ports Click the Performance Ethernet Ether Ports Statistics tabsClick the Provisioning Ethernet POS Ports tabs 18-23DLP-F326 View Asap STM-N PM Parameters Click the Performance Ethernet POS Ports Statistics tabsClick the Performance Optical tabs Figure 18-24DLP-F327 View Asap Ether Ports Statistics PM Parameters 18-2518-26 Ether Ports Statistics in the Card View Performance WindowDLP-F328 View Asap Ether Ports Utilization PM Parameters 18-27DLP-F329 View Asap POS Ports Statistics PM Parameters 18-28DLP-F330 View Asap POS Ports Utilization PM Parameters 18-29DLP-F331 View Asap POS Ports History PM Parameters 18-30DLP-F332 Change Node Access and PM Clearing Privilege 18-3118-32 DLP-F333 Install the Asap Carrier Modules 18-33DLP-F334 Verify Pass-Through Circuits 18-34DLP-F335 Preprovision an SFP 18-35DLP-F336 Print CTC Data 18-36DLP-F337 View Asap Ether Ports History PM Parameters 18-3718-38 18-39 Click the Provisioning MS-SPRing tabsClick Create MS-SPRing DLP-F339 Create a Two-Fiber MS-SPRing Manually 18-40DLP-F340 Change an MS-SPRing Node ID 18-41DLP-F341 MS-SPRing Exercise Ring Test 18-42DLP-F342 MS-SPRing Switch Test 18-4318-44 Click the Maintenance MS-SPRing tabsClick Retrieve 18-45 18-46 18-47 DLP-F344 Initiate an MS-SPRing Manual Ring SwitchDLP-F343 Provision an STM-N Circuit Route 18-48 DLP-F345 Clear an MS-SPRing Manual Ring SwitchOnsite/Remote Onsite Security Level Provisioning or higher DLP-F346 Create an MS-SPRing on a Single Node 18-49DLP-F347 Initiate an MS-SPRing Force Ring Switch 18-50DLP-F348 View Circuit Information 18-512F-PCA DRIPCA Sncp18-53 18-54 PendingmergeDroppending 11 Connecting Fiber to a Four-Node, Two-Fiber MS-SPRing 18-55DLP-F350 Delete an MS-SPRing from a Single Node 18-5618-57 12 Selecting Single Roll Attributes18-58 14 Selecting a New Endpoint18-59 15 Viewing the Rolls Tab18-60 18-61 Click the Circuits tab 18-6218-63 17 Selecting Dual Roll Attributes18 Setting Roll Routing Preferences 18-6418-65 18-66 18-67 18-68 18-69 DLP-F356 Delete a RollClick the Circuits Rolls tabs 18-70 DLP-F357 Cancel a RollDLP-F358 Provision a Multirate PPM 18-71 DLP-F359 Change the Optical Line RateClick the Provisioning Pluggable Port Modules tabs DLP-F360 Delete a PPM 18-72DLP-F361 Provision OSI Routing Mode 18-7318-74 Node view, click the Provisioning OSI Tarp Config tabsDLP-F362 Provision or Modify Tarp Operating Parameters 18-75 18-76 Node view, click the Provisioning OSI Tarp Static TDC tabsClick Add Static Entry 18-77 DLP-F365 Add a Tarp Manual Adjacency Table EntryClick Delete Static Entry 18-78 Click the Provisioning OSI Routers Setup tabsDLP-F366 Provision OSI Routers 18-79 DLP-F368 Enable the OSI Subnet on the LAN InterfaceDLP-F367 Provision Additional Manual Area Addresses 18-80 DLP-F369 Create an IP-Over-CLNS TunnelClick the Provisioning OSI Tunnels tabs DLP-F370 Remove a Tarp Manual Adjacency Table Entry 18-81DLP-F371 Change the OSI Routing Mode 18-82DLP-F372 Edit the OSI Router Configuration 18-83DLP-F373 Edit the OSI Subnetwork Point of Attachment DLP-F374 Edit an IP-Over-CLNS TunnelNode view, click the Provisioning OSI Routers Subnet tabs 18-84DLP-F375 Delete an IP-Over-CLNS Tunnel 18-85DLP-F376 View IS-IS Routing Information Base 18-8618-87 DLP-F377 View ES-IS Routing Information BaseDLP-F378 Manage the Tarp Data Cache DLP-F379 Export CTC Data 18-8818-89 19 Selecting CTC Data for ExportDLP-F380 Configure the Node for Radius Authentication 18-9018-91 20 Radius Server Tab18-92 DLP-F381 Delete a Server TrailClick the Provisioning Server Trails tabs 18-93 DLP-F383 Download an Alarm Severity ProfileDLP-F382 Grant Superuser Privileges to a Provisioning User 18-94 DLP-F384 Install the Asap 1PIO and 4PIO PIM Modules 18-9518-96 22 1PIO Module FaceplateDLP-F385 Consolidate Links in Network View 18-9724shows a network view with unconsolidated DCC and PPC links 18-9818-99 ALLDwdm GCC, OTS, PPC TDM 18-100 DLP-F386 Adjust the Java Virtual Memory Heap SizeDLP-F387 Install an SFP/XFP DLP-F388 Remove an SFP/XFP 18-101DLP-F389 Remove a 1PIO or 4PIO PIM Module 18-102DLP-F390 Provision an Optical Line Rate and Wavelength Asap 4PIO1PIO Click the Provisioning Optical Line tabs18-104 DLP-F391 Install Alarm Wires on the CAP/CAP2CAP/CAP2 18-105 27 Rear of the ONS 15600 SDH, Including the CAP/CAP218-106 28 CAP/CAP2 Faceplate and ConnectionsDLP-F392 Change Line Transmission Settings for STM-N Cards 18-10718-108 SF BERSD BER Sonet 18-10918-110 SetsSTU DLP-F393 Change Threshold Settings for STM-N Ports 18-11118-112 DLP-F394 Change Optics Threshold Settings for STM-N Ports 18-113Refresh 18-11418-115 DLP-F395 Change the STM-N Port ALS Maintenance SettingsClick the Maintenance ALS tabs DLP-F396 Clear All PM Thresholds 18-116DLP-F397 Provision the Designated Socks Servers 18-11718-118 18-119 18-120