2 – QCP2330/2332 FCode
Q
3.Set the QCP2330/2332 HBA loop ID (see section 2.4.3).
4.Select the boot device (see section 2.4.4).
5.Build the bootable disk (see section 2.4.5).
2.4.1
Updating FCode on the QCP2330/2332 HBA
If you need to update the FCode on the QCP2330/2332 HBA, use the QLogic qla2x00 flash utility. A QLogic Solaris SPARC driver revision 3.06 or later must be installed before the flash utility can be run.
WARNING!! Be very careful when changing flash contents; incorrect data may render the QCP2330/2332 HBA unusable to the point that the operating system may no longer function.
Perform the following steps to run the flash utility:
1.Copy the qla2x00flash file and the ifp2300.prom file to the desired directory.
2.At the command line, enter the appropriate path. Use the information obtained with the
./qla2x00flash
2.4.2
Setting the QCP2330/2332 HBA Connection Mode
Perform the following steps to view the current QCP2330/2332 HBA connection mode and change it if necessary:
1.To view the current connection mode, type the
ok
The connection mode and options display. For example:
Current HBA connection mode: 1 -
Possible connection mode choices: 0 - Loop Only
1-
2- Loop preferred, otherwise
2.If the connection mode is not correct based on the devices connected to the QCP2330/2332 HBA, change it using the
ok 0