Q-Logic 2300 series manual Solaris Sparc Driver Installation, Introduction

Page 57

Section 6

Solaris SPARC Driver Installation

(QL2300)

6.1

Introduction

This section provides instructions for installing the Solaris SPARC driver in an already installed Solaris SPARC operating system. The naming convention for the drivers, associated files, and messages is QLA; however, the Solaris SPARC driver supports standard QLogic PCI HBAs (QLAxxxx), cPCI HBAs (QCPxxxx), and SBus HBAs (QSBxxxx).

The latest version of the Solaris SPARC driver package is available on the QLogic web site (www.qlogic.com). The files in the driver package cannot be read nor installed from a DOS environment. Be sure to review the Readme.txt file for both new and changed information.

To install the driver from a CD-ROM, see section 6.3. To install the driver from the QLogic Web site, see section 6.4. If you are installing the driver from another media, for example, a floppy disk, transfer the qla2300.Z file to a temporary directory on the machine where the driver will be installed, then continue with step 4 in section 6.4.

6.2

Pre-installation Requirements

Before you install the Solaris driver, uninstall any existing QLA2300 driver using the pkgrm utility.

NOTE:

If you are uninstalling Solaris driver version 4.07 or later, the Solaris pkgrm utility creates a backup copy of the qla2300.conf configuration file in the /kernel/drv directory.

If you are uninstalling a driver version before 4.07, QLogic recommends that you manually create a backup copy of the qla2300.conf configuration file.

To upgrade from qla2300 driver version 4.11 (and earlier) to qla2300 driver version 4.12 (and above), you must remove the appropriate qla2300 driver package before installing the new one, even though the package name has been changed and may not appear to be conflicting.

CF2351102-00 F

6-1

Image 57
Contents SANblade 2300 Series User’s Guide Page Table of Contents Section QSB2340/2342 Figures Page What is Fibre Channel? How to Use this GuideIntroduction General DescriptionCompliance with the following PCI standards QCP HBAs FeaturesHardware Hardware CF2351102-00 F QCP2330/2332 QCP2330/2332 HBA ComponentsLEDs Installation and Removal Installation in the Computer StandardJumpers ApId Type Receptacle Occupant Condition Installation in the Computer Hot SwapSystem configuration is as follows FCode Removing the QCP2330/2332 HBASetting the QCP2330/2332 HBA Connection Mode Connection mode and options display. For exampleUpdating FCode on the QCP2330/2332 HBA Selecting the Boot Device Setting the QCP2330/2332 HBA Loop IDNew connection mode displays. For example Loop ID displays. For exampleFollowing displays Building the Bootable DiskQCP2330/2332 FCode Install the boot block on the new boot disk. For example Use the rm command to delete the restoresymtable fileBoot from the newly created boot disk. For example Setting and Viewing the Fibre Channel Data RateView the current dump device setting. For example Shut down the system. Type the followingTables 2-2and 2-3define the QCP2330/2332 specifications SpecificationsAgency Certification LabelEMC/EMI Test Requirements Conducted EmissionProduct Safety Requirements QCP2340/2342 HBA Components QCP2340/2342LED1 and LED2 QCP2342 Activity Installation in the Computer Hot Swap ApId Type Receptacle Occupant Condition System configuration is as follows Removing the QCP2340/2342 HBA Updating FCode on the QCP2340/2342 HBA Setting the QCP2340/2342 HBA Connection ModeSetting the QCP2340/2342 HBA Loop ID Selecting the Boot Device Building the Bootable Disk Use the rm command to delete the restoresymtable file Shut down the system. Type the following QCP2340/2342 Board Operating Environment Tables 3-3and 3-4define the QCP2340/2342 specificationsDMA EMI and EMC RequirementsEN550221995 Class a Radiated Emission QCP2340/2342 Agency Certification CF2351102-00 F QSB2340/2342 HBA Components QSB2340/2342Installation in the Computer Updating FCode on the QSB2340/2342 HBA Setting the QSB2340/2342 HBA Loop ID Setting the QSB2340/2342 HBA Connection ModeFor example Building the Bootable Disk QSB2340/2342 FCode Ufsdump 0f /ufstestore rf Shutdown the system. Type the following Tables 4-2and 4-3define the QSB2340/2342 specificationsClass B QSB2340/2342 Agency Certification QSB2340/2342 Agency Certification CF2351102-00 F Problems After Installation TroubleshootingHardware Problem Checklist Fibre Channel Problem ChecklistPage Software II Software II-2 CF2351102-00 F Solaris Sparc Driver Installation Pre-installation RequirementsIntroduction Continue with in section Installing the Solaris Sparc Driver from a CD-ROMPress Enter to continue You are prompted to select a driver package. For exampleInstalling QLogic QLA2300 driver as QLA2300 Type the following text to reboot and reconfigure the system Solaris Sparc Driver Installation FCode CF2351102-00 F