Q-Logic 2300 series manual System configuration is as follows

Page 29

Q

3 – QCP2340/2342 Installation and Removal

4.Type the cfgadm command (see step 2) to verify that the system recognizes the QCP2340/2342 HBA and that the HBA is not configured. In the following example, the QCP2340/2342 HBA has been installed in slot 4 and is not configured.

Ap_Id

Type

Receptacle

Occupant

Condition

N0.IB6

cPCI_I/O_bo

connected

configured

ok

N0.IB8

unknown

empty

unconfigured

unknown

N0.SB0

CPU_Board

connected

configured

ok

N0.SB2

CPU_Board

connected

configured

ok

c0

scsi-bus

connected

configured

unknown

pcisch0:sg6slot2

stpcipci/fhs

connected

configured

ok

pcisch0:sg6slot3

unknown

empty

unconfigured

unknown

pcisc1:sg6slot0

unknown

empty

unconfigured

unknown

 

 

 

unconfigured

 

pcisch2:sg6slot4

unknown

disconnected

unknown

 

 

 

unconfigured

 

pcisch2:sg6slot5

unknown

connected

unknown

pcisch3:sg6slot1

unknown

empty

unconfigured

unknown

5. Type the following commands to configure the QCP2340/2342 HBA:

cfgadm -c configure slot path

For example, type the following commands to configure the QCP2340/2342 HBA in slot 4, as shown in step 4:

cfgadm -c configure pcisch2:sg6slot4

The system configuration is as follows:

Ap_Id

Type

Receptacle

Occupant

Condition

N0.IB6

cPCI_I/O_bo

connected

configured

ok

N0.IB8

unknown

empty

unconfigured

unknown

N0.SB0

CPU_Board

connected

configured

ok

N0.SB2

CPU_Board

connected

configured

ok

c0

scsi-bus

connected

configured

unknown

pcisch0:sg6slot2

stpcipci/fhs

connected

configured

ok

pcisch0:sg6slot3

unknown

empty

unconfigured

unknown

pcisc1:sg6slot0

unknown

empty

unconfigured

unknown

 

 

 

configured

 

pcisch2:sg6slot4

stpcipci/fhs

connected

ok

 

 

 

unconfigured

 

pcisch2:sg6slot5

unknown

connected

unknown

pcisch3:sg6slot1

unknown

empty

unconfigured

unknown

CF2351102-00 F

3-5

Image 29
Contents SANblade 2300 Series User’s Guide Page Table of Contents Section QSB2340/2342 Figures Page What is Fibre Channel? How to Use this GuideIntroduction General DescriptionCompliance with the following PCI standards QCP HBAs FeaturesHardware Hardware CF2351102-00 F LEDs QCP2330/2332QCP2330/2332 HBA Components Jumpers Installation and RemovalInstallation in the Computer Standard ApId Type Receptacle Occupant Condition Installation in the Computer Hot SwapSystem configuration is as follows FCode Removing the QCP2330/2332 HBAUpdating FCode on the QCP2330/2332 HBA Setting the QCP2330/2332 HBA Connection ModeConnection mode and options display. For example Selecting the Boot Device Setting the QCP2330/2332 HBA Loop IDNew connection mode displays. For example Loop ID displays. For exampleFollowing displays Building the Bootable DiskQCP2330/2332 FCode Install the boot block on the new boot disk. For example Use the rm command to delete the restoresymtable fileBoot from the newly created boot disk. For example Setting and Viewing the Fibre Channel Data RateView the current dump device setting. For example Shut down the system. Type the followingTables 2-2and 2-3define the QCP2330/2332 specifications SpecificationsAgency Certification LabelEMC/EMI Test Requirements Conducted EmissionProduct Safety Requirements QCP2340/2342 HBA Components QCP2340/2342LED1 and LED2 QCP2342 Activity Installation in the Computer Hot Swap ApId Type Receptacle Occupant Condition System configuration is as follows Removing the QCP2340/2342 HBA Updating FCode on the QCP2340/2342 HBA Setting the QCP2340/2342 HBA Connection ModeSetting the QCP2340/2342 HBA Loop ID Selecting the Boot Device Building the Bootable Disk Use the rm command to delete the restoresymtable file Shut down the system. Type the following QCP2340/2342 Board Operating Environment Tables 3-3and 3-4define the QCP2340/2342 specificationsDMA EMI and EMC RequirementsEN550221995 Class a Radiated Emission QCP2340/2342 Agency Certification CF2351102-00 F QSB2340/2342 HBA Components QSB2340/2342Installation in the Computer Updating FCode on the QSB2340/2342 HBA Setting the QSB2340/2342 HBA Loop ID Setting the QSB2340/2342 HBA Connection ModeFor example Building the Bootable Disk QSB2340/2342 FCode Ufsdump 0f /ufstestore rf Shutdown the system. Type the following Tables 4-2and 4-3define the QSB2340/2342 specificationsClass B QSB2340/2342 Agency Certification QSB2340/2342 Agency Certification CF2351102-00 F Problems After Installation TroubleshootingHardware Problem Checklist Fibre Channel Problem ChecklistPage Software II Software II-2 CF2351102-00 F Introduction Solaris Sparc Driver InstallationPre-installation Requirements Continue with in section Installing the Solaris Sparc Driver from a CD-ROMPress Enter to continue You are prompted to select a driver package. For exampleInstalling QLogic QLA2300 driver as QLA2300 Type the following text to reboot and reconfigure the system Solaris Sparc Driver Installation FCode CF2351102-00 F