Sun Microsystems 96257 manual Hazardous Materials Handling, Standards Conformance

Page 12

Hazardous Materials Handling

Lead-acid battery packs and lithium-battery cards used in the VSM-VTSS are classified as hazardous materials. Sun personnel are required to comply with U.S. Department of Transportation (DOT), International Civil Aviation Organization (ICAO) and International Maritime Dangerous Goods (IMDG) Code requirements for shipping, recycling, and dis- posal of hazardous materials. If you have questions about these requirements, contact the Sun Environmental Health and Safety (EHS) group in Louisville, Colorado (USA).

Standards Conformance

This VSM5-VTSS system conforms to all necessary North American (U.S./Canada) and international standards for product safety, electromagnetic compatibility (EMC), body schemes, and binary multiples as defined below.

Product Safety Standards

This VSM5-VTSS system complies with the following product safety standards:

Underwriters Laboratories (UL) – Listed by Underwriters Laboratories UL 1950, Infor- mation Technology Equipment, Third Edition

Canadian Standards Association (CSA) – Certified to Canadian Standards Association, CAN/CSA C22.2 No. 950-95, Information Technology Equipment, Third Edition

International Electrotechnical Commission (IEC) – Complies with IEC Publication 950, Safety Information Technology Equipment through TUV (Technischer Ueberwachungs- verein)

Electromagnetic Compatibility

This VSM5-VTSS system complies with the following referenced standards for electro- magnetic compatibility (EMC):

United States: Federal Communications Commission (FCC) – This equipment complies with FCC Title 47, Part 15 Subpart B, Unintentional Radiators Class A.

FCC Compliance Statement: This equipment has been tested and found to comply to the limits for Class A digital devices pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equip- ment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed in accordance with the instruction man- ual, may cause harmful interference to radio communications. Operation of this equip- ment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense.

Canada: Canadian Department of Communications (CDC) – This equipment complies with Canadian EMC law CDC ICES-003.

European Union (CE Mark) – This equipment complies with Electromagnetic Compatibility Directive 89/336 (as amended).

96257

Sun Confidential: Internal Only

xii

 

Revision A

 

Image 12
Contents StorageTek Page Virtual Tape Storage Subsystem Vtss Export Destination Control Statement Disclaimer of Warranties and Limitation of LiabilityProprietary Information Statement Revision a SeptemberRevision History / Summary of Changes SAPContents 96257 Sun Confidential Internal Only Vii Revision a Implementation Planning Site Readiness Planning96257 Sun Confidential Internal Only Viii Revision a Figures Tables Warranty Notice Class 1 Laser Product NoticeCabling Notice Product Safety Standards Hazardous Materials HandlingStandards Conformance Electromagnetic CompatibilityPage Internal Code License Statement DefinitionsSafety / Fiber Optic / ESD Precautions Safety PrecautionsElectrostatic Discharge Precautions Strictly Comply With Caution and Warning MessagesFiber Optic Component Handling Precautions Protect Your EyesOptimizing Content For Electronic Viewing About This GuideProduct Overview Intended AudienceAlert Messages Notational and Typographic ConventionsExamples Description of Convention Where to Find Additional Information Reference DocumentsVSM Engineering Website Colophon SE Support ToolsPlanning and Implementation Overview System Assurance Process FlowCreating Planning Teams Planning / Readiness / Implementation Timelines Page Configuration Planning Configuration Planning OverviewKey High-Level Activities Key Sub-Tasks Key Participants Defining Customer Requirements VSM Quick Tool Tool Selection ScreenVSM Sizer Tool VSM Sizer ToolMVC Sizer Tool MVC Sizer ToolMVC Migration Tool MVC Migration ToolCDS Sizer Tool CDS Sizer ToolVtss Configuration Planning VSM5-VTSS Physical CharacteristicsVSM5-VTSS Physical Characteristics VSM5-VTSS Environmental RequirementsModel Numbers / Configurations / Capacities VSM5-VTSS Model Numbers / Configurations / CapacitiesPrerequisites for Ficon Connectivity Additional Prerequisites for Ficon RTDsNative Ficon Attachment Native Ficon Attachment OptionsFicon Data Transfer Rates Ficon Cabling Short-Wave vs. Long-Wave ConnectionsSingle-Mode vs. Multi-Mode Ficon Cabling VCF3 Ficon Card Configuration Examples Ficon Channel Card Configuration 4 VCF CardsFicon Channel Card Configuration 6 VCF Cards Fibre Channel Cables Available Lengths Fibre Channel Cables Available LengthsDescription / Length Part Number AC Source Power Specifications and Connectors DC Power Supply Voltage Ripple SpecificationsVSM5-VTSS AC Source Power Specifications and Connectors VSM5-VTSS DC Power Supply Voltage RipplePower Requirements Implementation Planning Implementation Planning OverviewPage Site Readiness Planning Site Readiness Planning OverviewSite Evaluation External Considerations Site Evaluation Internal ConsiderationsStructural Dimensions and Obstructions Transfering Equipment Point-to-PointData Center Safety Emergency Power ControlSite Power Distribution Systems Site Electrical Power Distribution SystemSource Power Requirements for VSM5 Equipment Source Power Voltage Range Frequency Range HzElectrostatic Discharge Hvac RequirementsEnvironmental Requirements and Hazards Floor Construction RequirementsFloor Loading Requirements VSM5-VTSS Floor Loading Specifications Site Evaluation Internal ConsiderationsVSM5-VTSS Cabinet Superimposed Floor Loading Example VSM5-VTSS Cabinet Weight Distribution and Leveler Locations Raised Flooring Horizontal Force ChartVSM5-VTSS Cabinet Dimensions for Physical Space Planning Physical Space RequirementsPage Specifications and Additional Information Motherboard and FRU Interconnections Side Motherboard and FRU Interconnections Side Power Safety Grounding Diagram Side Figure A-3. VSM5-VTSS Power Safety Grounding Diagram SideFigure A-4. VSM5-VTSS Power Safety Grounding Diagram Side Power System Diagram Figure A-5. VSM5-VTSS Power System DiagramData Paths and Interfaces Figure A-6. VSM5-VTSS Data Paths and InterfacesFiber Optic Cable Specifications VShell Command ReferenceTable A-1. Fiber Optic Cable Specifications Table A-2. VShell Command ReferenceSample Iocp Gen for Ficon Configuration Figure A-7. Sample Iocp Gen for Ficon ConfigurationVirtual Tape Drive Mapping and Host Addressing Sequential Device Parameters NumbersFRU Identifiers Table A-4. VSM5-VTSS FRU IdentifiersHex Decimal Unit.Tray.Slot Logic Motherboard and Cards ISP1Hex Decimal Unit.Tray.Slot Logic Power Supply Fans Card Cage ImpellersPhysical Array Disk Drive Tray Hex Decimal Unit.Tray.Slot Physical Array Disk Drive Tray DA.5.DRV0 Array Drive Module Status Descriptions Figure A-8. Array Drive Module States and RelationshipsTable A-5. Array Drive Module Status Descriptions Media Acceptance Test MAT PartitionSpares Partition Unavailable PartitionPage Ficon Channel Extension Guidelines Definition of Terms General Channel Extension Considerations Understand Channel Extension Performance LimitationsPlacement of Extension Equipment Interoperability TestingFicon Topologies Ficon Channel Extension Sample Configurations Channel Director/Switch ExtenderTape Silo HostFigure B-4. VTSS-to-RTD Channel Extension Direct Attachment McData/CNT Channel Extension Interoperability McData/CNT Channel Extension InteroperabilityISL Failover Is Supported Only in Shuttle Mode Cisco Systems Channel Extension Interoperability Page Glossary Sun Confidential Internal Only 96257 Revision a 96257 Sun Confidential Internal Only Revision a Data compression. See compression 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Functional device. See functional volume Technology with ISO 96257 Sun Confidential Internal Only Revision a MLC. Machine-Level Control Part number Service Delivery Platform SDP. a Sun StorageTek 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Forms and Reference Notes Host System Configuration Information Customer Personnel Contacts Sun StorageTek / QSP Personnel Contacts Planning Worksheet 1 Planning Worksheet 2 Planning Worksheet 3 Planning Worksheet 4 Planning Worksheet 5 Software Information Hardware Information Tape Devices Hardware Information Switches / Routers Hardware Information SDP and Modem Devices Account Account Account Account Account Page Headquarters