VTSS Configuration Planning
■VTSS Configuration Planning
A VSM5 system consists of Virtual Tape Control System (VTCS) host software, Virtual Tape Storage Subsystem (VTSS) disk hardware (tape buffers)1, real tape drives (RTDs) which attach to an Automated Cartridge System (ACS), and automated cartridge systems (ACSs), a.k.a. tape libraries.
A
VSM5-VTSS Environmental Requirements
Table 2-2. VSM5-VTSS Environmental Requirements
Environmental | Shipping Environment | Storage Environment | Operating Environment | |
Factor | Limits* | Limits# | Limits | |
Temperature | 10oC to 40 C | 16oC to 32oC | ||
(50o F to 104o F) | (60o F to 90o F) | |||
| ||||
Thermal Change | 15 C | 15oC | 5oC | |
(maximum rate/hr) | (27o F) | (27o F) | (9o F) | |
Humidity‡ | 10% to 80% | 10% to 80% | 20% to 80% | |
Altitude | 0m to 15,240m | 0m to 3050m | 0m to 2439m | |
(0 ft. to 50,000 ft.) | (0 ft. to 10,000 ft.) | (0 ft. to 8000 ft.) | ||
| ||||
|
|
|
|
Notes:
• Abbreviations key: C = Centigrade; F = Fahrenheit; ft. = foot / feet; m = meter(s)
• * The shipping environment must not exceed the storage environment limits longer than 10 days.
• # The storage environment must not exceed the operating environment limits longer than 60 days.
• ‡ Humidity specifications exclude conditions that may cause condensation on disk drives.
VSM5-VTSS Physical Characteristics
Table 2-3. VSM5-VTSS Physical Characteristics
Physical Attribute | Specification | |
Height | 154.94cm (61.0 in.) | |
|
| |
Width (with both side covers attached) | 92.1cm (36.24 in.) | |
Depth (with front and rear doors attached) | 77.1cm (30.34 in.) | |
|
| |
Maximum Weight (with 64 array drives) | 445kg (982 lbs.) | |
Footprint | 7093.7cm2 (1099.5 in2) | |
Recommended Service Clearance, Front/Rear (door swing radius) | 54.1cm | (21.3 in.) |
Recommended Left/Right Side Clearance (optional) | 6.4cm | (2.5 in.) |
|
|
|
1.Both a primary VTSS and secondary VTSS can be used within a single system configuration.
2.Including, but not limited to: OS/390, z/OS, MVS, and VM host systems and FICON directors (switches) by Brocade, CNT, and McData. Check with Sun product marketing for the latest certification and compatibility information for VSM systems.
96257 | Sun Confidential: Internal Only | |
| Revision A |
|