Sun Microsystems 96257 manual Sun Confidential Internal Only Revision a

Page 87

CD-ROM. Compact Disc Read-Only Memory. An optical disc that may contain computer data, audio data, graph- ics, and other information, and is interchangeable be- tween different types of computers. Storage capacity is typically about 680 MB per disc.

CDS. Control data set. An HSC database containing all configuration and volume information, used by host soft- ware to control functions of automated libraries.

CEI. Configured end item.

CFE. Composite Failure Event. In VTSS, a structure formed for each discrete failure domain.

CFT. Controlled field test.

change journal. In VSM, the record of changes to the functional track directory (FTD) that is kept in nonvolatile storage (NVS) and is then written to the disk arrays (VTSS). VSM uses the change journal to reconstruct the FTD in the event of a failure.

channel. (1) A point-to-point link whose primary task is to transport data from one point to another. (2) A path for transfer of data and control information between a disk drive and array controller. (3) A device that connects a host and main storage with the I/O control units.

channel image. A software image that logically presents itself as a single physical channel, regardless of how the physical connection is made. Each channel image ap- pears to be an independent single physical channel, al- though all channel images on a specific I/O interface share the same facilities and physical paths. A VSM5- VTSS presents up to 16 control unit images to each of 1 to 28 host systems.

channel interface. Controller circuitry that attaches host channels.

check0. An error condition detected within a VTSS pro- cessor card that affects the integrity of the processor. If a second check 0 is detected within the same processor during recovery, the processor hard-stops (a ‘double check 0’ condition), making the operation or condition unrecoverable by the failing processor.

check1. An error condition that affects a control bus or shared memory bus but leaves processor cards function- al. Check1 may affect all processors on a bus, since the bus is locked until the condition is cleared.

check2. An error condition detected in the non-proces- sor logic cards.

checksum. A value that accompanies data transferred between points to ensure the data is transferred correct- ly. Checksum is computed by adding up the bytes or words of a data block. On the receiving end, checksum is computed based on the data received and compared with the value that was sent with the data. If the two numbers match, the data is considered to be correct.

CHPID. Channel-path identifier. A value assigned to an installed channel path that provides for its discrete recog- nition by a VTSS.

circuit breaker. A switch that automatically interrupts an electrical circuit when there is an overload of current or other abnormal condition.

CKD. See count-key data.

client. A system which is able to operate independently but has some degree of dependence on another system. Frequently refers to computers on a LAN. A client is a re- cipient of services in a client/server application. Clients can be workstations, PCs, or other servers.

client/server. A system architecture in which one or

more programs (clients) request computing or data ser- vices, such as data storage, processing, or transmission, from another program (server).

clink. clustered link. An ESCON port used to link a mas- ter and slave VTSS in a clustered configuration.

clock speed. In storage systems, the frequency at which the system clock oscillates, as measured in MHz. The faster the clock, the more quickly the system can trans- mit information.

clustering. (1) In VSM, the process of writing a virtual tape volume (VTV) onto two discrete VTSSs. (2) A tech- nique for configuring two or more servers as a single pro- cessing system using software and hardware to allow sharing of storage, processing, and other resources un- der a single management domain, thereby providing greater data accessibility and higher reliability.

CM. Configuration Management. (1) Identification and management of physical product configurations through documentation, records, and data. (2) An organization within Sun responsible for applying these disciplines through a formal EC process.

cold boot. The act of switching a computer, storage sys- tem, etc. Completely off, then switching it back on again. Contrast with warm boot.

cold swap. To remove and replace a system component (typically one such as a logic board that has no redun- dant backup) after system operations have been stopped and power has been disabled. Contrast with hot swap.

collected free space. Array cylinders that are collected and completely free of user data.

collocation. A process that attempts to keep all data be- longing to a single client node on a minimal number of sequential-access media volumes within a storage pool. Used to minimize the number of volumes that must be accessed when a large amount of data must be restored.

command line interface. A user interface in which com- mands are keyed onto a command line instead of through a Graphical User Interface. Contrast with GUI.

compaction. The elimination of inter-record gaps nor- mally associated with count-key data DASD that allows less disk storage space to be used, reducing net capaci- ty load in VTSS units.

compression. The process of encoding data using algo- rithms so that it uses less storage space and/or increas- es the rate, or speed, of data transmission.

Configuration Control Document (CCD). A Sun docu- ment which defines model numbers, family ID codes, feature codes, part numbers, etc. for a specific product, and which identifies the configured end items (CEIs) available for use in the product.

Configuration Status Monitor (CSM). In VTSS, a part of the Failure Management System (FMS) that monitors FRU configurations in the controller, performs FRU vali- dation, and coordinates diagnostic fencing.

controlled power-down (CPD). An orderly sequence of steps that shuts off AC power to a system without jeopar- dizing customer data.

controller. A system control module or storage control unit. Also called a control module or control unit. See al- so disk array controller.

control region. VTSS data path control. Hardware in a multipath controller that is associated with a data path and which transfers data between the cache and disk ar- rays and between cache and host channel(s).

96257

Sun Confidential: Internal Only

C-87

 

Revision A

 

Image 87
Contents StorageTek Page Virtual Tape Storage Subsystem Vtss Revision a September Export Destination Control StatementDisclaimer of Warranties and Limitation of Liability Proprietary Information StatementSAP Revision History / Summary of ChangesContents Implementation Planning Site Readiness Planning 96257 Sun Confidential Internal Only Vii Revision a96257 Sun Confidential Internal Only Viii Revision a Figures Tables Warranty Notice Class 1 Laser Product NoticeCabling Notice Electromagnetic Compatibility Product Safety StandardsHazardous Materials Handling Standards ConformancePage Definitions Internal Code License StatementSafety Precautions Safety / Fiber Optic / ESD PrecautionsStrictly Comply With Caution and Warning Messages Electrostatic Discharge PrecautionsProtect Your Eyes Fiber Optic Component Handling PrecautionsIntended Audience Optimizing Content For Electronic ViewingAbout This Guide Product OverviewAlert Messages Notational and Typographic ConventionsExamples Description of Convention Reference Documents Where to Find Additional InformationVSM Engineering Website SE Support Tools ColophonSystem Assurance Process Flow Planning and Implementation OverviewCreating Planning Teams Planning / Readiness / Implementation Timelines Page Configuration Planning Configuration Planning OverviewKey High-Level Activities Key Sub-Tasks Key Participants VSM Quick Tool Tool Selection Screen Defining Customer RequirementsVSM Sizer Tool VSM Sizer ToolMVC Sizer Tool MVC Sizer ToolMVC Migration Tool MVC Migration ToolCDS Sizer Tool CDS Sizer ToolVSM5-VTSS Environmental Requirements Vtss Configuration PlanningVSM5-VTSS Physical Characteristics VSM5-VTSS Physical CharacteristicsVSM5-VTSS Model Numbers / Configurations / Capacities Model Numbers / Configurations / CapacitiesAdditional Prerequisites for Ficon RTDs Prerequisites for Ficon ConnectivityNative Ficon Attachment Options Native Ficon AttachmentFicon Data Transfer Rates Ficon Cabling Short-Wave vs. Long-Wave ConnectionsSingle-Mode vs. Multi-Mode Ficon Cabling Ficon Channel Card Configuration 4 VCF Cards VCF3 Ficon Card Configuration ExamplesFicon Channel Card Configuration 6 VCF Cards Fibre Channel Cables Available Lengths Fibre Channel Cables Available LengthsDescription / Length Part Number VSM5-VTSS DC Power Supply Voltage Ripple AC Source Power Specifications and ConnectorsDC Power Supply Voltage Ripple Specifications VSM5-VTSS AC Source Power Specifications and ConnectorsPower Requirements Implementation Planning Overview Implementation PlanningPage Site Readiness Planning Overview Site Readiness PlanningSite Evaluation Internal Considerations Site Evaluation External ConsiderationsTransfering Equipment Point-to-Point Structural Dimensions and ObstructionsEmergency Power Control Data Center SafetySite Electrical Power Distribution System Site Power Distribution SystemsSource Power Voltage Range Frequency Range Hz Source Power Requirements for VSM5 EquipmentHvac Requirements Electrostatic DischargeEnvironmental Requirements and Hazards Floor Construction RequirementsFloor Loading Requirements VSM5-VTSS Floor Loading Specifications Site Evaluation Internal ConsiderationsVSM5-VTSS Cabinet Superimposed Floor Loading Example Raised Flooring Horizontal Force Chart VSM5-VTSS Cabinet Weight Distribution and Leveler LocationsPhysical Space Requirements VSM5-VTSS Cabinet Dimensions for Physical Space PlanningPage Specifications and Additional Information Motherboard and FRU Interconnections Side Motherboard and FRU Interconnections Side Figure A-3. VSM5-VTSS Power Safety Grounding Diagram Side Power Safety Grounding Diagram SideFigure A-4. VSM5-VTSS Power Safety Grounding Diagram Side Figure A-5. VSM5-VTSS Power System Diagram Power System DiagramFigure A-6. VSM5-VTSS Data Paths and Interfaces Data Paths and InterfacesTable A-2. VShell Command Reference Fiber Optic Cable SpecificationsVShell Command Reference Table A-1. Fiber Optic Cable SpecificationsFigure A-7. Sample Iocp Gen for Ficon Configuration Sample Iocp Gen for Ficon ConfigurationSequential Device Parameters Numbers Virtual Tape Drive Mapping and Host AddressingTable A-4. VSM5-VTSS FRU Identifiers FRU IdentifiersISP1 Hex Decimal Unit.Tray.Slot Logic Motherboard and CardsHex Decimal Unit.Tray.Slot Logic Power Supply Fans Card Cage ImpellersPhysical Array Disk Drive Tray Hex Decimal Unit.Tray.Slot Physical Array Disk Drive Tray DA.5.DRV0 Figure A-8. Array Drive Module States and Relationships Array Drive Module Status DescriptionsUnavailable Partition Table A-5. Array Drive Module Status DescriptionsMedia Acceptance Test MAT Partition Spares PartitionPage Ficon Channel Extension Guidelines Definition of Terms Understand Channel Extension Performance Limitations General Channel Extension ConsiderationsPlacement of Extension Equipment Interoperability TestingFicon Topologies Host Ficon Channel Extension Sample ConfigurationsChannel Director/Switch Extender Tape SiloFigure B-4. VTSS-to-RTD Channel Extension Direct Attachment McData/CNT Channel Extension Interoperability McData/CNT Channel Extension InteroperabilityISL Failover Is Supported Only in Shuttle Mode Cisco Systems Channel Extension Interoperability Page Glossary Sun Confidential Internal Only 96257 Revision a 96257 Sun Confidential Internal Only Revision a Data compression. See compression 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Functional device. See functional volume Technology with ISO 96257 Sun Confidential Internal Only Revision a MLC. Machine-Level Control Part number Service Delivery Platform SDP. a Sun StorageTek 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Forms and Reference Notes Host System Configuration Information Customer Personnel Contacts Sun StorageTek / QSP Personnel Contacts Planning Worksheet 1 Planning Worksheet 2 Planning Worksheet 3 Planning Worksheet 4 Planning Worksheet 5 Software Information Hardware Information Tape Devices Hardware Information Switches / Routers Hardware Information SDP and Modem Devices Account Account Account Account Account Page Headquarters