Fibre Channel (FC). An ANSI-standard serial interface used to provide high-speed data transfers between work- stations, servers, desktop computers, peripherals and, more recently, as a channel for attachment of storage devices. FC allows concurrent communication between connected elements. FC topologies include Fibre Chan- nel-Arbitrated Loop (FC-AL), point-to-point, and switched fabric.

FICON. FIbre CONnection. An IBM S/390-based chan- nel architecture that provides up to 256 channels in a single connection, each having a capacity of 100 MB per second.

file. A set of related records treated as a unit.

fixed-block architecture (FBA) device. A disk storage device that stores data in blocks of fixed size; these blocks are addressed by block number relative to the be- ginning of the particular file. Contrast with count-key data device.

fixed mapping. A mapping technique where the location of a mapped object is a fixed, computable function of the identity of the mapped object and a description of the mapping scheme. See also mapping. Contrast with dy- namic mapping.

foreground. A mode of operation where tasks are per- formed on a high-priority basis as soon as possible, de- pending on available resources. Contrast with back- ground.

F_Port. Fabric port. Also written as F_PORT. FLOGIN. Fabric login.

FL_Port. Fabric port with loop capability.

free space. Back-end disk array storage space that does not contain user data.

free space collection. In VSM, an automatic back- ground task that relocates data from fragmented VTSS disk cylinders and collects the resulting free space into empty cylinders, making write operations more efficient.

free space directory. In VSM, an internal microcode structure that contains the free space list and free cylin- der list.

front end. The portion of a VTSS controller data path that passes data between channels and cache.

FRU. Field-replaceable unit. The smallest self-contained part or component in a system that can be individually replaced during a service or repair action.

FSC. See Fault Symptom Code.

FTD. See Functional Track Directory.

FTR. See Functional Track Recovery.

full-duplex. A communications channel that transmits data in both directions at once. Contrast with half-duplex.

functional. In VTSS, a view or description of stored data encompassing physical and/or logical elements. Con- trast with logical, physical.

functional allocated space. A user-allocated portion of functional volume space; i.e., datasets as defined in a VTOC, or minidisks as defined in a VM directory.

functional capacity. The amount of data that can be stored on a VTSS, as viewed by a host.

functional device. See functional volume.

functional device identifier (FDID). A unique numeric identifier (an integer from 1 to 1023) for a functional vol-

ume image as known to a VTSS.

functional device ID mapping. The correlation between the FDID and the host system identification for a specific functional volume image. See also mapping.

functional free space. The unallocated and/or unused portion of the space on a functional volume as defined in the VTOC or VM directory.

functional stored space. The used portion of functional allocated space for a specific functional volume.

functional-to-logical mapping. The relationship be- tween functional devices and logical devices. See map- ping. See also fixed mapping, dynamic mapping.

functional track record. A record stored on contiguous sectors in an allocated array cylinder.

Functional Track Directory (FTD). A VTSS internal mapping table that contains one entry for each functional track associated with the functional volumes currently defined by the user.

functional track recovery (FTR). In VSM, an automatic process of recovering data from a physical track in a VTSS disk drive that is unreadable due to a media defect or failed device, accomplished by reading and process- ing data and redundancy information at corresponding physical track locations on remaining devices in an array.

functional volume. A logical object in a data storage pool that is used to store data; a data carrier that is mounted or demounted as a unit; a volume image that a host system receives when the ‘read device characteris- tics’ channel command word is issued.

G

GA. General Availability. A Sun StorageTek term indicat- ing a date after which a product is generally available to all customers.

Gb. Gigabit. A unit of data capacity equal to one billion (1,000,000,000 or 109) bits. One gigabit is equal to one thousand megabits or one million kilobits. Also abbreviat- ed gbit or Gbit. Contrast with bit, kilobit, megabit.

GB. Gigabyte. A unit of data capacity roughly equal to one billion (1,000,000,000 or 109) bytes. One gigabyte is equal to one thousand megabytes or one million kilo- bytes. Also abbreviated as gbyte, Gbyte. Contrast with byte, kilobyte, megabyte, petabyte, terabyte.

Gbps. Gigabits per second (billion bits per second). GBps. Gigabytes per second (billion bytes per second). GFI. Guided Fault Isolation.

GFR. Guided FRU Replacement. A utility in the VTSS support facility that defines and coordinates FRU re- placement, and manages FRU isolation and FRU swaps.

ground. A conducting connection, whether intentional or accidental, between an electrical circuit or equipment and the earth. The position or portion of an electrical cir- cuit at zero potential with respect to the earth. A conduct- ing connection to such a position or to the earth. A large conducting body used as a return for electrical currents and as an arbitrary zero of potential.

GUI. Graphical user interface. A generic name for any computer interface that substitutes graphics for charac- ters on a computer screen or console, and which usually works with a navigational device such as a mouse or trackball. Contrast with command line interface.

96257

Sun Confidential: Internal Only

C-91

 

Revision A

 

Image 91
Contents StorageTek Page Virtual Tape Storage Subsystem Vtss Revision a September Export Destination Control StatementDisclaimer of Warranties and Limitation of Liability Proprietary Information StatementSAP Revision History / Summary of ChangesContents Implementation Planning Site Readiness Planning 96257 Sun Confidential Internal Only Vii Revision a96257 Sun Confidential Internal Only Viii Revision a Figures Tables Class 1 Laser Product Notice Warranty NoticeCabling Notice Electromagnetic Compatibility Product Safety StandardsHazardous Materials Handling Standards ConformancePage Definitions Internal Code License StatementSafety Precautions Safety / Fiber Optic / ESD PrecautionsStrictly Comply With Caution and Warning Messages Electrostatic Discharge PrecautionsProtect Your Eyes Fiber Optic Component Handling PrecautionsIntended Audience Optimizing Content For Electronic ViewingAbout This Guide Product OverviewNotational and Typographic Conventions Alert MessagesExamples Description of Convention Reference Documents Where to Find Additional InformationVSM Engineering Website SE Support Tools ColophonSystem Assurance Process Flow Planning and Implementation OverviewCreating Planning Teams Planning / Readiness / Implementation Timelines Page Configuration Planning Overview Configuration PlanningKey High-Level Activities Key Sub-Tasks Key Participants VSM Quick Tool Tool Selection Screen Defining Customer RequirementsVSM Sizer Tool VSM Sizer ToolMVC Sizer Tool MVC Sizer ToolMVC Migration Tool MVC Migration ToolCDS Sizer Tool CDS Sizer ToolVSM5-VTSS Environmental Requirements Vtss Configuration PlanningVSM5-VTSS Physical Characteristics VSM5-VTSS Physical CharacteristicsVSM5-VTSS Model Numbers / Configurations / Capacities Model Numbers / Configurations / CapacitiesAdditional Prerequisites for Ficon RTDs Prerequisites for Ficon ConnectivityNative Ficon Attachment Options Native Ficon AttachmentFicon Cabling Short-Wave vs. Long-Wave Connections Ficon Data Transfer RatesSingle-Mode vs. Multi-Mode Ficon Cabling Ficon Channel Card Configuration 4 VCF Cards VCF3 Ficon Card Configuration ExamplesFicon Channel Card Configuration 6 VCF Cards Fibre Channel Cables Available Lengths Fibre Channel Cables Available LengthsDescription / Length Part Number VSM5-VTSS DC Power Supply Voltage Ripple AC Source Power Specifications and ConnectorsDC Power Supply Voltage Ripple Specifications VSM5-VTSS AC Source Power Specifications and ConnectorsPower Requirements Implementation Planning Overview Implementation PlanningPage Site Readiness Planning Overview Site Readiness PlanningSite Evaluation Internal Considerations Site Evaluation External ConsiderationsTransfering Equipment Point-to-Point Structural Dimensions and ObstructionsEmergency Power Control Data Center SafetySite Electrical Power Distribution System Site Power Distribution SystemsSource Power Voltage Range Frequency Range Hz Source Power Requirements for VSM5 EquipmentHvac Requirements Electrostatic DischargeFloor Construction Requirements Environmental Requirements and HazardsFloor Loading Requirements Site Evaluation Internal Considerations VSM5-VTSS Floor Loading SpecificationsVSM5-VTSS Cabinet Superimposed Floor Loading Example Raised Flooring Horizontal Force Chart VSM5-VTSS Cabinet Weight Distribution and Leveler LocationsPhysical Space Requirements VSM5-VTSS Cabinet Dimensions for Physical Space PlanningPage Specifications and Additional Information Motherboard and FRU Interconnections Side Motherboard and FRU Interconnections Side Figure A-3. VSM5-VTSS Power Safety Grounding Diagram Side Power Safety Grounding Diagram SideFigure A-4. VSM5-VTSS Power Safety Grounding Diagram Side Figure A-5. VSM5-VTSS Power System Diagram Power System DiagramFigure A-6. VSM5-VTSS Data Paths and Interfaces Data Paths and InterfacesTable A-2. VShell Command Reference Fiber Optic Cable SpecificationsVShell Command Reference Table A-1. Fiber Optic Cable SpecificationsFigure A-7. Sample Iocp Gen for Ficon Configuration Sample Iocp Gen for Ficon ConfigurationSequential Device Parameters Numbers Virtual Tape Drive Mapping and Host AddressingTable A-4. VSM5-VTSS FRU Identifiers FRU IdentifiersISP1 Hex Decimal Unit.Tray.Slot Logic Motherboard and CardsCard Cage Impellers Hex Decimal Unit.Tray.Slot Logic Power Supply FansPhysical Array Disk Drive Tray Hex Decimal Unit.Tray.Slot Physical Array Disk Drive Tray DA.5.DRV0 Figure A-8. Array Drive Module States and Relationships Array Drive Module Status DescriptionsUnavailable Partition Table A-5. Array Drive Module Status DescriptionsMedia Acceptance Test MAT Partition Spares PartitionPage Ficon Channel Extension Guidelines Definition of Terms Understand Channel Extension Performance Limitations General Channel Extension ConsiderationsInteroperability Testing Placement of Extension EquipmentFicon Topologies Host Ficon Channel Extension Sample ConfigurationsChannel Director/Switch Extender Tape SiloFigure B-4. VTSS-to-RTD Channel Extension Direct Attachment McData/CNT Channel Extension Interoperability McData/CNT Channel Extension InteroperabilityISL Failover Is Supported Only in Shuttle Mode Cisco Systems Channel Extension Interoperability Page Glossary Sun Confidential Internal Only 96257 Revision a 96257 Sun Confidential Internal Only Revision a Data compression. See compression 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Functional device. See functional volume Technology with ISO 96257 Sun Confidential Internal Only Revision a MLC. Machine-Level Control Part number Service Delivery Platform SDP. a Sun StorageTek 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Forms and Reference Notes Host System Configuration Information Customer Personnel Contacts Sun StorageTek / QSP Personnel Contacts Planning Worksheet 1 Planning Worksheet 2 Planning Worksheet 3 Planning Worksheet 4 Planning Worksheet 5 Software Information Hardware Information Tape Devices Hardware Information Switches / Routers Hardware Information SDP and Modem Devices Account Account Account Account Account Page Headquarters