Fiber Optic Cable Specifications

Table A-1. Fiber Optic Cable Specifications

Optical Performance

Specification

 

 

Attenuation

1.0 dB/km @ 1300 nm

 

 

Bandwidth

500 MHz/km @ 2 km

Handling Characteristics

Specification

 

 

Pulling Strength

27.2 kg (60 lbs.)

 

 

Crush Resistance

650 Newtons/cm (371 ft-lbs/in2)

Minimum Bend Radius

96 mm (3.74 in.)

 

 

Cable Weight

59.7 kg/100 m (401 lbs./1000 ft.)

Bending Cycles

100 at minimum bend radius

 

 

Physical Environment

-16oC to +32o C (3.2o F to 89.6o F)

Note: Abbreviations key: C = centigrade; dB = decibel(s); F = Fahrenheit; ft. = foot / feet; in2 = inch(es) squared; km = kilometer(s); lb(s). = pound(s); m = meter(s); MHz = megahertz; mm = millimeter(s); nm = nanometer(s)

VShell Command Reference

Table A-2. VShell Command Reference

Command

Meaning / Description

Status avail

Displays Subsystem Availability screen

 

 

Status subsystem

Displays Subsystem Configuration and Status screen

Status cfes

Lists current Composite Failure Events (CFEs)

 

 

Status ispdrive

Lists status of ISP hard drives and shown which SRL are preloaded

Status adrives prod

Lists all HDAs assigned in production arrays

 

 

Status adrives spares

Lists all HDAs assigned as global spares

Status adrives unavail

Lists all HDAs unavailable for use (including U.B.—unavailable broken)

 

 

Status interfaces

Displays Subsystem Interface Status screen

Status channels

Displays Channel Configuration Status screen

 

 

Ecu

Preloads EC upgrade microcode

Hicstat $

Displays and downloads hic_stat.dia file to a selected current drive

 

 

Realtime

Lists DOP Status field messages in real time; useful for monitoring system IML

Showsrl

Lists the system release level (SRL) that is currently running on the VTSS

 

 

State <name>

Downloads the named state save file to a selected current drive

Allstate $

Downloads all state saves and associated files to a selected current drive

 

 

Help

Displays online help file for all commands; click [Enter] to close

Help <command>

Displays online help file with information about the named command

 

 

A-64

Sun Confidential: Internal Only

96257

 

Revision A

 

Image 64
Contents StorageTek Page Virtual Tape Storage Subsystem Vtss Export Destination Control Statement Disclaimer of Warranties and Limitation of LiabilityProprietary Information Statement Revision a SeptemberRevision History / Summary of Changes SAPContents 96257 Sun Confidential Internal Only Vii Revision a Implementation Planning Site Readiness Planning96257 Sun Confidential Internal Only Viii Revision a Figures Tables Class 1 Laser Product Notice Warranty NoticeCabling Notice Product Safety Standards Hazardous Materials HandlingStandards Conformance Electromagnetic CompatibilityPage Internal Code License Statement DefinitionsSafety / Fiber Optic / ESD Precautions Safety PrecautionsElectrostatic Discharge Precautions Strictly Comply With Caution and Warning MessagesFiber Optic Component Handling Precautions Protect Your EyesOptimizing Content For Electronic Viewing About This GuideProduct Overview Intended AudienceNotational and Typographic Conventions Alert MessagesExamples Description of Convention Where to Find Additional Information Reference DocumentsVSM Engineering Website Colophon SE Support ToolsPlanning and Implementation Overview System Assurance Process FlowCreating Planning Teams Planning / Readiness / Implementation Timelines Page Configuration Planning Overview Configuration PlanningKey High-Level Activities Key Sub-Tasks Key Participants Defining Customer Requirements VSM Quick Tool Tool Selection ScreenVSM Sizer Tool VSM Sizer ToolMVC Sizer Tool MVC Sizer ToolMVC Migration Tool MVC Migration ToolCDS Sizer Tool CDS Sizer ToolVtss Configuration Planning VSM5-VTSS Physical CharacteristicsVSM5-VTSS Physical Characteristics VSM5-VTSS Environmental RequirementsModel Numbers / Configurations / Capacities VSM5-VTSS Model Numbers / Configurations / CapacitiesPrerequisites for Ficon Connectivity Additional Prerequisites for Ficon RTDsNative Ficon Attachment Native Ficon Attachment OptionsFicon Cabling Short-Wave vs. Long-Wave Connections Ficon Data Transfer RatesSingle-Mode vs. Multi-Mode Ficon Cabling VCF3 Ficon Card Configuration Examples Ficon Channel Card Configuration 4 VCF CardsFicon Channel Card Configuration 6 VCF Cards Fibre Channel Cables Available Lengths Fibre Channel Cables Available LengthsDescription / Length Part Number AC Source Power Specifications and Connectors DC Power Supply Voltage Ripple SpecificationsVSM5-VTSS AC Source Power Specifications and Connectors VSM5-VTSS DC Power Supply Voltage RipplePower Requirements Implementation Planning Implementation Planning OverviewPage Site Readiness Planning Site Readiness Planning OverviewSite Evaluation External Considerations Site Evaluation Internal ConsiderationsStructural Dimensions and Obstructions Transfering Equipment Point-to-PointData Center Safety Emergency Power ControlSite Power Distribution Systems Site Electrical Power Distribution SystemSource Power Requirements for VSM5 Equipment Source Power Voltage Range Frequency Range HzElectrostatic Discharge Hvac RequirementsFloor Construction Requirements Environmental Requirements and HazardsFloor Loading Requirements Site Evaluation Internal Considerations VSM5-VTSS Floor Loading SpecificationsVSM5-VTSS Cabinet Superimposed Floor Loading Example VSM5-VTSS Cabinet Weight Distribution and Leveler Locations Raised Flooring Horizontal Force ChartVSM5-VTSS Cabinet Dimensions for Physical Space Planning Physical Space RequirementsPage Specifications and Additional Information Motherboard and FRU Interconnections Side Motherboard and FRU Interconnections Side Power Safety Grounding Diagram Side Figure A-3. VSM5-VTSS Power Safety Grounding Diagram SideFigure A-4. VSM5-VTSS Power Safety Grounding Diagram Side Power System Diagram Figure A-5. VSM5-VTSS Power System DiagramData Paths and Interfaces Figure A-6. VSM5-VTSS Data Paths and InterfacesFiber Optic Cable Specifications VShell Command ReferenceTable A-1. Fiber Optic Cable Specifications Table A-2. VShell Command ReferenceSample Iocp Gen for Ficon Configuration Figure A-7. Sample Iocp Gen for Ficon ConfigurationVirtual Tape Drive Mapping and Host Addressing Sequential Device Parameters NumbersFRU Identifiers Table A-4. VSM5-VTSS FRU IdentifiersHex Decimal Unit.Tray.Slot Logic Motherboard and Cards ISP1Card Cage Impellers Hex Decimal Unit.Tray.Slot Logic Power Supply FansPhysical Array Disk Drive Tray Hex Decimal Unit.Tray.Slot Physical Array Disk Drive Tray DA.5.DRV0 Array Drive Module Status Descriptions Figure A-8. Array Drive Module States and RelationshipsTable A-5. Array Drive Module Status Descriptions Media Acceptance Test MAT PartitionSpares Partition Unavailable PartitionPage Ficon Channel Extension Guidelines Definition of Terms General Channel Extension Considerations Understand Channel Extension Performance LimitationsInteroperability Testing Placement of Extension EquipmentFicon Topologies Ficon Channel Extension Sample Configurations Channel Director/Switch ExtenderTape Silo HostFigure B-4. VTSS-to-RTD Channel Extension Direct Attachment McData/CNT Channel Extension Interoperability McData/CNT Channel Extension InteroperabilityISL Failover Is Supported Only in Shuttle Mode Cisco Systems Channel Extension Interoperability Page Glossary Sun Confidential Internal Only 96257 Revision a 96257 Sun Confidential Internal Only Revision a Data compression. See compression 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Functional device. See functional volume Technology with ISO 96257 Sun Confidential Internal Only Revision a MLC. Machine-Level Control Part number Service Delivery Platform SDP. a Sun StorageTek 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Forms and Reference Notes Host System Configuration Information Customer Personnel Contacts Sun StorageTek / QSP Personnel Contacts Planning Worksheet 1 Planning Worksheet 2 Planning Worksheet 3 Planning Worksheet 4 Planning Worksheet 5 Software Information Hardware Information Tape Devices Hardware Information Switches / Routers Hardware Information SDP and Modem Devices Account Account Account Account Account Page Headquarters