Sun Microsystems 96257 manual Table A-4. VSM5-VTSS FRU Identifiers

Page 67

FRU Identifiers

FRU Identifiers

Table A-4. VSM5-VTSS FRU Identifiers

Physical

FRU

 

FRU

FRU Number

FRU Number

FRU Location ID

Location

Common Name

 

Silkscreen

(Hex)

(Decimal)

(Unit.Tray.Slot)

 

Power Distribution Units

 

 

CU Front Tray 0

Power Distribution Unit 0

 

PDU2-O

4E

78

CU.0.PDU0

 

 

 

 

 

 

 

CU Front Tray 0

Power Distribution Unit 1

 

PDU2-1

4F

79

CU.0.PDU1

 

 

 

 

 

 

 

Inside PDU0

PDU0 Internal Fan

 

FAN 0

3C1

961

CU.0.FAN0

 

 

 

 

 

 

 

Inside PDU1

PDU1 Internal Fan

 

FAN 1

3C2

962

CU.0.FAN0

 

 

 

 

 

 

 

 

 

Maintenance Pod

 

 

CU MPOD Tray

Battery Charger Unit

 

IBCU-0

4C

76

CU.3.BCU0

 

 

 

 

 

 

 

CU MPOD Tray

Battery Charger Unit

 

IBCU-1

4D

77

CU.3.BCU1

 

 

 

 

 

 

 

CU MPOD Tray

ISP Hard Drive

 

HD2-0

384

900

CU.3.HD0

 

 

 

 

 

 

 

CU MPOD Tray

ISP Hard Drive

 

HD2-1

385

901

CU.3.HD1

 

 

 

 

 

 

 

CU MPOD Tray

5v/12v Power Supply

 

AUHP-0

388

904

CU.3.AUHP0

 

 

 

 

 

 

 

CU MPOD Tray

5v/12v Power Supply

 

AUHP-1

389

905

CU.3.AUHP1

CU MPOD Tray

A-Hub Card

 

??

 

386

902

CU.3.???

Faceplate Assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CU MPOD Tray

Battery Pack

 

BAT-0

394

916

CU.3.BAT0

 

 

 

 

 

 

 

CU MPOD Tray

Battery Pack

 

BAT-1

395

917

CU.3.BAT1

 

 

 

 

 

 

 

CU Front Tray 3

Power Control Panel

 

PPNL

387

903

CU.3.PPNL

 

 

 

 

 

 

 

 

 

 

DC Power Supplies

 

 

 

CU Rear Tray 1

Logic Power Supply 0

 

LPS2-0

 

1A

26

CU.1.LPS0

 

 

 

 

 

 

 

 

CU Rear Tray 1

Logic Power Supply 1

 

LPS2-1

 

1B

27

CU.1.LPS1

 

 

 

 

 

 

 

 

DA Rear Tray 0

Array Power Supply 0

 

APS-0

 

94

148

DA.0.APS

 

 

 

 

 

 

 

 

DA Rear Tray 1

Array Power Supply 1

 

APS-1

 

95

149

DA.1.APS

 

 

 

 

 

 

 

 

DA Rear Tray 2

Array Power Supply 2

 

APS-2

 

A8

168

DA.2.APS

 

 

 

 

 

 

 

 

DA Rear Tray 3

Array Power Supply 3

 

APS-3

 

A9

169

DA.3.APS

 

 

 

 

 

 

 

 

DA Rear Tray 4

Array Power Supply 4

 

APS-4

 

F8

248

DA.4.APS

 

 

 

 

 

 

 

 

DA Rear Tray 5

Array Power Supply 5

 

APS-5

 

F9

249

DA.5.APS

 

 

 

 

 

 

 

 

DA Rear Tray 6

Array Power Supply 6

 

APS-6

 

10C

268

DA.6.APS

 

 

 

 

 

 

 

 

DA Rear Tray 7

Array Power Supply 7

 

APS-7

 

10D

269

DA.7.APS

 

 

 

 

 

 

 

 

96257

Sun Confidential: Internal Only

A-67

 

Revision A

 

Image 67
Contents StorageTek Page Virtual Tape Storage Subsystem Vtss Revision a September Export Destination Control StatementDisclaimer of Warranties and Limitation of Liability Proprietary Information StatementSAP Revision History / Summary of ChangesContents Implementation Planning Site Readiness Planning 96257 Sun Confidential Internal Only Vii Revision a96257 Sun Confidential Internal Only Viii Revision a Figures Tables Class 1 Laser Product Notice Warranty NoticeCabling Notice Electromagnetic Compatibility Product Safety StandardsHazardous Materials Handling Standards ConformancePage Definitions Internal Code License StatementSafety Precautions Safety / Fiber Optic / ESD PrecautionsStrictly Comply With Caution and Warning Messages Electrostatic Discharge PrecautionsProtect Your Eyes Fiber Optic Component Handling PrecautionsIntended Audience Optimizing Content For Electronic ViewingAbout This Guide Product OverviewNotational and Typographic Conventions Alert MessagesExamples Description of Convention Reference Documents Where to Find Additional InformationVSM Engineering Website SE Support Tools ColophonSystem Assurance Process Flow Planning and Implementation OverviewCreating Planning Teams Planning / Readiness / Implementation Timelines Page Configuration Planning Overview Configuration PlanningKey High-Level Activities Key Sub-Tasks Key Participants VSM Quick Tool Tool Selection Screen Defining Customer RequirementsVSM Sizer Tool VSM Sizer ToolMVC Sizer Tool MVC Sizer ToolMVC Migration Tool MVC Migration ToolCDS Sizer Tool CDS Sizer ToolVSM5-VTSS Environmental Requirements Vtss Configuration PlanningVSM5-VTSS Physical Characteristics VSM5-VTSS Physical CharacteristicsVSM5-VTSS Model Numbers / Configurations / Capacities Model Numbers / Configurations / CapacitiesAdditional Prerequisites for Ficon RTDs Prerequisites for Ficon ConnectivityNative Ficon Attachment Options Native Ficon AttachmentFicon Cabling Short-Wave vs. Long-Wave Connections Ficon Data Transfer RatesSingle-Mode vs. Multi-Mode Ficon Cabling Ficon Channel Card Configuration 4 VCF Cards VCF3 Ficon Card Configuration ExamplesFicon Channel Card Configuration 6 VCF Cards Fibre Channel Cables Available Lengths Fibre Channel Cables Available LengthsDescription / Length Part Number VSM5-VTSS DC Power Supply Voltage Ripple AC Source Power Specifications and ConnectorsDC Power Supply Voltage Ripple Specifications VSM5-VTSS AC Source Power Specifications and ConnectorsPower Requirements Implementation Planning Overview Implementation PlanningPage Site Readiness Planning Overview Site Readiness PlanningSite Evaluation Internal Considerations Site Evaluation External ConsiderationsTransfering Equipment Point-to-Point Structural Dimensions and ObstructionsEmergency Power Control Data Center SafetySite Electrical Power Distribution System Site Power Distribution SystemsSource Power Voltage Range Frequency Range Hz Source Power Requirements for VSM5 EquipmentHvac Requirements Electrostatic DischargeFloor Construction Requirements Environmental Requirements and HazardsFloor Loading Requirements Site Evaluation Internal Considerations VSM5-VTSS Floor Loading SpecificationsVSM5-VTSS Cabinet Superimposed Floor Loading Example Raised Flooring Horizontal Force Chart VSM5-VTSS Cabinet Weight Distribution and Leveler LocationsPhysical Space Requirements VSM5-VTSS Cabinet Dimensions for Physical Space PlanningPage Specifications and Additional Information Motherboard and FRU Interconnections Side Motherboard and FRU Interconnections Side Figure A-3. VSM5-VTSS Power Safety Grounding Diagram Side Power Safety Grounding Diagram SideFigure A-4. VSM5-VTSS Power Safety Grounding Diagram Side Figure A-5. VSM5-VTSS Power System Diagram Power System DiagramFigure A-6. VSM5-VTSS Data Paths and Interfaces Data Paths and InterfacesTable A-2. VShell Command Reference Fiber Optic Cable SpecificationsVShell Command Reference Table A-1. Fiber Optic Cable SpecificationsFigure A-7. Sample Iocp Gen for Ficon Configuration Sample Iocp Gen for Ficon ConfigurationSequential Device Parameters Numbers Virtual Tape Drive Mapping and Host AddressingTable A-4. VSM5-VTSS FRU Identifiers FRU IdentifiersISP1 Hex Decimal Unit.Tray.Slot Logic Motherboard and CardsCard Cage Impellers Hex Decimal Unit.Tray.Slot Logic Power Supply FansPhysical Array Disk Drive Tray Hex Decimal Unit.Tray.Slot Physical Array Disk Drive Tray DA.5.DRV0 Figure A-8. Array Drive Module States and Relationships Array Drive Module Status DescriptionsUnavailable Partition Table A-5. Array Drive Module Status DescriptionsMedia Acceptance Test MAT Partition Spares PartitionPage Ficon Channel Extension Guidelines Definition of Terms Understand Channel Extension Performance Limitations General Channel Extension ConsiderationsInteroperability Testing Placement of Extension EquipmentFicon Topologies Host Ficon Channel Extension Sample ConfigurationsChannel Director/Switch Extender Tape SiloFigure B-4. VTSS-to-RTD Channel Extension Direct Attachment McData/CNT Channel Extension Interoperability McData/CNT Channel Extension InteroperabilityISL Failover Is Supported Only in Shuttle Mode Cisco Systems Channel Extension Interoperability Page Glossary Sun Confidential Internal Only 96257 Revision a 96257 Sun Confidential Internal Only Revision a Data compression. See compression 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Functional device. See functional volume Technology with ISO 96257 Sun Confidential Internal Only Revision a MLC. Machine-Level Control Part number Service Delivery Platform SDP. a Sun StorageTek 96257 Sun Confidential Internal Only Revision a Sun Confidential Internal Only 96257 Revision a Forms and Reference Notes Host System Configuration Information Customer Personnel Contacts Sun StorageTek / QSP Personnel Contacts Planning Worksheet 1 Planning Worksheet 2 Planning Worksheet 3 Planning Worksheet 4 Planning Worksheet 5 Software Information Hardware Information Tape Devices Hardware Information Switches / Routers Hardware Information SDP and Modem Devices Account Account Account Account Account Page Headquarters