Omron BU3002SW, BU1002SW specifications Explanation of symbols used on unit

Page 18

1. Preparation

1-4 Explanation of symbols used on unit

Symbol

Description

Start the UPS.

Stop the UPS.

Suspend a beep.

UPS output power enabled, supplied by operating on line mode, battery mode.

UPS operating on battery mode.

Additional battery unit connected to the UPS. (For BU100XS only.)

Error occurred with UPS.

Batteries at end of useful life, necessary to replace the batteries.

16

Image 18
Contents BU1002SW/BU3002SW Introduction Internal Battery Procedure from installation to operation Start Installation/connectionTable of Contents Safety precautions Keep plastic package bags out of reach of childrenMisuse may cause death or serious injury Provide secure grounding Do not disassemble, repair, or modify the unitDo not pinch or tie the cable of the unit Doing so may compromise the safety of devices Do not allow the unit to come in contact with water If fluid leaks from the unit, do not touch the fluidUse a specified battery for replacement Do not insert metal objects into the battery connectorsPerform replacement on a stable and flat place Do not disassemble or modify the batteryDo not put the battery into fire and do not break it Do not use a new battery and an old battery at the same timeDo not perform a withstand voltage test Scheduled operation using the UPS monitoring software Quitting Battery ModeRebooting This unit uses lead acid batteries2Checking the contents PreparationUnpacking the product Name of each part Front viewSide view Rear view BU1002SW BU3002SWExplanation of symbols used on unit Installation and connection Precautions and notes on installation and connectionDo not install the unit in other than specified orientations Installation and connection Do not perform a withstand voltage test Installation and connection BU1002SWBU3002SW Casters locked Connecting the equipment Group control of power supply outputConnecting a device to the power supply output BU1002SW Output on Output OFFNfpa Input plug L6-15P Front view Connecting a device to the power supply output BU3002SW BU3002SW Rated value of output capacity Max kVA/2100WRear panel Input plug L6-20P Front view Turn on the units power switch Checking the operationBring all the connected devices into operation Battery Mode, check the units LED display and beep sound OFFCharging the battery Measuring the initial value of backup timeRecharging the battery Precautions and notes for operation OperationExplanation Start and stop procedures and basic operation Start procedureOperation Turn on the power switch of the UPS Operation after a power failure Setting switch 1 can be used to turn the beeper ON/OFF.Operation during recovery from a power failure Stop procedureConnection capacity/battery level meter Interpreting beeps and displays Displays and beeps in normal operationDisplay and beep for battery replacement UPS functions Suspending a beepSelf-diagnosis test Description of the auto battery test function Changing the setting of the functionsSetting switch function list UPS functions BS signal reception time corresponds to the setting switch BS signal valid range setting setting switch UPS operation mode settings Settings available for this operation are shown belowSettable items and explanations OFF Settings Cold start Estimated backup time Measuring the backup timeHow to measure backup time For Windows Server 2003/XP/Me/2000/Windows NT/Linux/MacBUM100S Life of battery estimated replacement timing Maintenance and InspectionChecking the battery Methods for checking the batteryReplacing the battery Battery recycling Procedure for recycling the batteryDo not hold the connector or cable of the battery pack Tighten the 2 screws Battery replacement is now complete Red tape Tighten 2 screws After replacing the battery during operation Replacing the fan Do not put your fingers into the fanFan replacement procedure Cleaning Cleaning the UPSUsing the UPS monitoring software and contact signal UPS monitoring softwareSoftware title Connect the UPS to a computer RS-232CWhen using UPS Power Manager UPS monitoring software for Mac When connecting 2 or more computers to the UPSExplanation Install the included UPS service driver on the computer Connector Perform UPS service setup ClickRecycling and Discarding the Battery Stopping the UPSHow to set up UPS service set the time to shut down Windows Check Set ClickCheck Set Check Set Signal output Contact signalContact Signal Low battery level signal output BLItems that can be set using the contact signal card Remote ON/OFF SignalOutput delay time setting for backup signal output BU BU/BL signal reverse output settingInsert/ removal method of contact signal card Contact Signal Connector female DSUB9PContact Signal circuit inside the UPS Remote ON/OFF connectorContact Signal ratings Example of the use of the Contact Signal circuitPrecautions and notes for the use of the Contact Signal Remote ON/OFF circuitUsing an SNMP/Web card Adding an SNMP/Web cardDescription features SpecificationsSNMP/Web card outline Extending the backup time Connecting an additional battery unitAdding BUM300S to the BU3002SW Troubleshooting Problem Check and remedySpecifications ReferencesDimensions BU3002SWCircuit block diagram Related productsK1L-D-06051B