Omron BU1002SW, BU3002SW specifications Do not allow the unit to come in contact with water

Page 9

Safety precautions

Caution (for use)

Never touch the metal part of the input plug if it is disconnected while the unit is operating.

Doing so may result in electric shock.

The leak current of this product itself is less than the value of the safety standard (leak current: 1 mA). However, because connected equipment causes the leak current to increase, you must never touch the metal part of the input plug.

When the unit is operating, voltage is generated in the metal parts of the input plug via ca- pacitors in the internal circuit, regardless of the elapsed time.

Do not allow the unit to come in contact with water.

Doing so may cause an electric shock or a fire.

If the unit becomes wet, stop using it and have it inspected and/or repaired. For repair, contact us:____________

When the battery is dead, replace it immediately or stop using the unit.

Continuing the use of it may cause a fire.

 

Ambient temperature

Expected life

 

 

 

 

 

 

20°C

4 to 5 years

* The values in the table are the expected life under standard

 

30°C

2 to 2.5 years

use conditions and are not guaranteed.

 

 

 

 

Using a dry cloth, periodically wipe the dust from the AC input plug, power supply output receptacles and output terminal block.

Accumulated dust may cause a fire.

Do not use the unit in a closed place and do not cover the unit.

Doing so may cause abnormal heating or a fire.

If you notice abnormal sound or smell, smoke, or leakage from the inside, immediately turn off the power switch and disconnect the AC input plug from a wall outlet (commercial power).

Using the unit under such conditions may cause a fire.

If you notice such a condition, stop using the unit and contact us at _____ for inspection and repairs.

Use the unit under the conditions in which you can immediately disconnect the AC input plug from a wall outlet (commercial power) in the case of an abnormal event.

If fluid leaks from the unit, do not touch the fluid.

Doing so may cause blindness or burns.

If the fluid contacts your eyes or skin, wash it out with lots of clean water and consult your doctor.

Do not place objects on the unit that are 25 kg or heavier, and do not drop metal objects onto the unit.

Doing so may cause distortion/damage to the case or a failure of the internal circuit, which may cause a fire.

7

Image 9
Contents BU1002SW/BU3002SW Introduction Internal Battery Start Installation/connection Procedure from installation to operationTable of Contents Safety precautions Keep plastic package bags out of reach of childrenMisuse may cause death or serious injury Provide secure grounding Do not disassemble, repair, or modify the unitDo not pinch or tie the cable of the unit Doing so may compromise the safety of devices If fluid leaks from the unit, do not touch the fluid Do not allow the unit to come in contact with waterPerform replacement on a stable and flat place Do not insert metal objects into the battery connectorsUse a specified battery for replacement Do not disassemble or modify the batteryDo not use a new battery and an old battery at the same time Do not put the battery into fire and do not break itDo not perform a withstand voltage test Rebooting Quitting Battery ModeScheduled operation using the UPS monitoring software This unit uses lead acid batteries2Checking the contents PreparationUnpacking the product Front view Name of each partSide view BU1002SW BU3002SW Rear viewExplanation of symbols used on unit Precautions and notes on installation and connection Installation and connectionDo not install the unit in other than specified orientations Installation and connection Do not perform a withstand voltage test BU1002SW Installation and connectionBU3002SW Casters locked Group control of power supply output Connecting the equipmentOutput on Output OFF Connecting a device to the power supply output BU1002SWNfpa Input plug L6-15P Front view BU3002SW Rated value of output capacity Max kVA/2100W Connecting a device to the power supply output BU3002SWRear panel Input plug L6-20P Front view Turn on the units power switch Checking the operationBring all the connected devices into operation OFF Battery Mode, check the units LED display and beep soundCharging the battery Measuring the initial value of backup timeRecharging the battery Operation Precautions and notes for operationExplanation Start and stop procedures and basic operation Start procedureOperation Turn on the power switch of the UPS Setting switch 1 can be used to turn the beeper ON/OFF. Operation after a power failureOperation during recovery from a power failure Stop procedureConnection capacity/battery level meter Displays and beeps in normal operation Interpreting beeps and displaysDisplay and beep for battery replacement UPS functions Suspending a beepSelf-diagnosis test Changing the setting of the functions Description of the auto battery test functionSetting switch function list UPS functions BS signal reception time corresponds to the setting switch BS signal valid range setting setting switch UPS operation mode settings Settings available for this operation are shown belowSettable items and explanations OFF Settings Cold start How to measure backup time Measuring the backup timeEstimated backup time For Windows Server 2003/XP/Me/2000/Windows NT/Linux/MacBUM100S Checking the battery Maintenance and InspectionLife of battery estimated replacement timing Methods for checking the batteryReplacing the battery Procedure for recycling the battery Battery recyclingDo not hold the connector or cable of the battery pack Tighten the 2 screws Battery replacement is now complete Red tape Tighten 2 screws After replacing the battery during operation Do not put your fingers into the fan Replacing the fanFan replacement procedure Cleaning the UPS CleaningUPS monitoring software Using the UPS monitoring software and contact signalSoftware title RS-232C Connect the UPS to a computerWhen connecting 2 or more computers to the UPS When using UPS Power Manager UPS monitoring software for MacExplanation Install the included UPS service driver on the computer Connector Click Perform UPS service setupStopping the UPS Recycling and Discarding the BatteryCheck Set Click How to set up UPS service set the time to shut down WindowsCheck Set Check Set Contact Signal Contact signalSignal output Low battery level signal output BLRemote ON/OFF Signal Items that can be set using the contact signal cardBU/BL signal reverse output setting Output delay time setting for backup signal output BUContact Signal Connector female DSUB9P Insert/ removal method of contact signal cardContact Signal ratings Remote ON/OFF connectorContact Signal circuit inside the UPS Example of the use of the Contact Signal circuitRemote ON/OFF circuit Precautions and notes for the use of the Contact SignalAdding an SNMP/Web card Using an SNMP/Web cardDescription features SpecificationsSNMP/Web card outline Connecting an additional battery unit Extending the backup timeAdding BUM300S to the BU3002SW Problem Check and remedy TroubleshootingReferences SpecificationsBU3002SW DimensionsRelated products Circuit block diagramK1L-D-06051B