Omron BU3002SW, BU1002SW specifications Circuit block diagram, Related products

Page 92

Reference

C. Circuit block diagram

 

 

 

Commercial

 

 

 

 

 

 

power bypass

 

 

 

 

 

 

output

 

 

 

200 to

Power supply

Rectifier

 

 

 

Power

relay

Inverter

 

 

240V AC

Noise

(high power

Filter

 

supply

(sine

 

input

filter

factor

 

output:

wave)

 

 

 

Input overcurrent

converter)

 

 

200/220/

 

 

 

 

 

protection

 

 

 

Output

230/240V AC

 

 

 

 

 

 

 

 

 

 

 

switching

 

 

 

 

Step-up

Control

Power supply

 

 

 

 

converter

circuit

switch

 

 

 

Charging

 

 

 

 

 

 

circuit

 

 

 

 

 

 

 

 

 

At startup/capacity exceeded/error

 

 

 

Battery

 

During Line mode

 

 

 

 

 

 

During Battery mode

D. Related products

Description

BU1002SW

BU3002SW

Replacement battery pack

BP100XS

BP150XS (two required)

Additional battery unit

BUM100S

BUM300S

Replacement fan

BUF1002S for rear fan

BUF1002S for rear fan

 

 

BUF3002S for front fan

Mounting bracket

BUP100S

BUP300S

SNMP/Web card

SC20G

Connection cable for Windows UPS service

BUC26

 

 

 

90

Image 92
Contents BU1002SW/BU3002SW Introduction Internal Battery Procedure from installation to operation Start Installation/connectionTable of Contents Misuse may cause death or serious injury Safety precautionsKeep plastic package bags out of reach of children Do not pinch or tie the cable of the unit Provide secure groundingDo not disassemble, repair, or modify the unit Doing so may compromise the safety of devices Do not allow the unit to come in contact with water If fluid leaks from the unit, do not touch the fluidDo not insert metal objects into the battery connectors Perform replacement on a stable and flat placeUse a specified battery for replacement Do not disassemble or modify the batteryDo not put the battery into fire and do not break it Do not use a new battery and an old battery at the same timeDo not perform a withstand voltage test Quitting Battery Mode RebootingScheduled operation using the UPS monitoring software This unit uses lead acid batteriesUnpacking the product 2Checking the contentsPreparation Name of each part Front viewSide view Rear view BU1002SW BU3002SWExplanation of symbols used on unit Installation and connection Precautions and notes on installation and connectionDo not install the unit in other than specified orientations Installation and connection Do not perform a withstand voltage test Installation and connection BU1002SWBU3002SW Casters locked Connecting the equipment Group control of power supply outputConnecting a device to the power supply output BU1002SW Output on Output OFFNfpa Input plug L6-15P Front view Connecting a device to the power supply output BU3002SW BU3002SW Rated value of output capacity Max kVA/2100WRear panel Input plug L6-20P Front view Bring all the connected devices into operation Turn on the units power switchChecking the operation Battery Mode, check the units LED display and beep sound OFFRecharging the battery Charging the batteryMeasuring the initial value of backup time Precautions and notes for operation OperationExplanation Operation Turn on the power switch of the UPS Start and stop procedures and basic operationStart procedure Operation after a power failure Setting switch 1 can be used to turn the beeper ON/OFF.Connection capacity/battery level meter Operation during recovery from a power failureStop procedure Interpreting beeps and displays Displays and beeps in normal operationDisplay and beep for battery replacement Self-diagnosis test UPS functionsSuspending a beep Description of the auto battery test function Changing the setting of the functionsSetting switch function list UPS functions BS signal reception time corresponds to the setting switch BS signal valid range setting setting switch Settable items and explanations UPS operation mode settingsSettings available for this operation are shown below OFF Settings Cold start Measuring the backup time How to measure backup timeEstimated backup time For Windows Server 2003/XP/Me/2000/Windows NT/Linux/MacBUM100S Maintenance and Inspection Checking the batteryLife of battery estimated replacement timing Methods for checking the batteryReplacing the battery Battery recycling Procedure for recycling the batteryDo not hold the connector or cable of the battery pack Tighten the 2 screws Battery replacement is now complete Red tape Tighten 2 screws After replacing the battery during operation Replacing the fan Do not put your fingers into the fanFan replacement procedure Cleaning Cleaning the UPSUsing the UPS monitoring software and contact signal UPS monitoring softwareSoftware title Connect the UPS to a computer RS-232CWhen using UPS Power Manager UPS monitoring software for Mac When connecting 2 or more computers to the UPSExplanation Install the included UPS service driver on the computer Connector Perform UPS service setup ClickRecycling and Discarding the Battery Stopping the UPSHow to set up UPS service set the time to shut down Windows Check Set ClickCheck Set Check Set Contact signal Contact SignalSignal output Low battery level signal output BLItems that can be set using the contact signal card Remote ON/OFF SignalOutput delay time setting for backup signal output BU BU/BL signal reverse output settingInsert/ removal method of contact signal card Contact Signal Connector female DSUB9PRemote ON/OFF connector Contact Signal ratingsContact Signal circuit inside the UPS Example of the use of the Contact Signal circuitPrecautions and notes for the use of the Contact Signal Remote ON/OFF circuitUsing an SNMP/Web card Adding an SNMP/Web cardSNMP/Web card outline Description featuresSpecifications Extending the backup time Connecting an additional battery unitAdding BUM300S to the BU3002SW Troubleshooting Problem Check and remedySpecifications ReferencesDimensions BU3002SWCircuit block diagram Related productsK1L-D-06051B