Omron BU3002SW Do not throw the unit into fire, Perform replacement on a stable and flat place

Page 10

Safety precautions

Caution (for maintenance)

When maintaining the connected equipment, turn OFF the power switch and disconnect the AC input plug.

Even if you disconnect the AC input plug while the UPS is operating, the power output of this unit does not stop and power is supplied from the outlet during a power failure.

Do not disassemble, repair, or modify the unit.

Doing so may cause an electric shock or a fire.

If fluid leaks from the unit, do not touch the fluid.

Doing so may cause blindness or burns.

If the fluid contacts your eyes or skin, wash it out with lots of clean water and consult your doctor.

Do not throw the unit into fire.

The lead battery in the unit may explode, or leak dilute sulfuric acid.

Do not insert metal objects into the power supply output receptacle or terminal block of the UPS.

Doing so may result in electric shock.

Do not insert metal objects into the battery connectors.

Doing so may result in electric shock.

Caution (for battery replacement)

Perform replacement on a stable and flat place.

Handle the battery carefully so that you do not drop it.

Not doing so could cause injury or burns due to liquid (acid) leakage.

Use a specified battery for replacement.

Not doing so may cause a fire.

Product model: BP100XS (Replacement battery pack for BU1002SW)

BP150XS: Two required (Replacement battery pack for BU3002SW)

Do not replace the battery in a place where there is flammable gas.

Spark may occur when connecting the battery, which may cause an explosion or fire.

If fluid (dilute sulfuric acid) leaks from the battery, do not touch the fluid.

Doing so may cause blindness or burns.

If it contacts your eyes or skin, wash it out with lots of clean water and consult your doctor.

Do not disassemble or modify the battery.

Doing so could cause dilute sulfuric acid leak, which could cause blindness and burns.

Do not drop the battery and do not expose it to strong impact.

Dilute sulfuric acid may leak.

Do not short the battery with metal objects.

Doing so could cause an electric shock, fire or burn.

Some electrical energy still remains inside the spent battery.

8

Image 10
Contents BU1002SW/BU3002SW Introduction Internal Battery Procedure from installation to operation Start Installation/connectionTable of Contents Keep plastic package bags out of reach of children Safety precautionsMisuse may cause death or serious injury Do not disassemble, repair, or modify the unit Provide secure groundingDo not pinch or tie the cable of the unit Doing so may compromise the safety of devices Do not allow the unit to come in contact with water If fluid leaks from the unit, do not touch the fluidUse a specified battery for replacement Do not insert metal objects into the battery connectorsPerform replacement on a stable and flat place Do not disassemble or modify the batteryDo not put the battery into fire and do not break it Do not use a new battery and an old battery at the same timeDo not perform a withstand voltage test Scheduled operation using the UPS monitoring software Quitting Battery ModeRebooting This unit uses lead acid batteriesPreparation 2Checking the contentsUnpacking the product Name of each part Front viewSide view Rear view BU1002SW BU3002SWExplanation of symbols used on unit Installation and connection Precautions and notes on installation and connectionDo not install the unit in other than specified orientations Installation and connection Do not perform a withstand voltage test Installation and connection BU1002SWBU3002SW Casters locked Connecting the equipment Group control of power supply outputConnecting a device to the power supply output BU1002SW Output on Output OFFNfpa Input plug L6-15P Front view Connecting a device to the power supply output BU3002SW BU3002SW Rated value of output capacity Max kVA/2100WRear panel Input plug L6-20P Front view Checking the operation Turn on the units power switchBring all the connected devices into operation Battery Mode, check the units LED display and beep sound OFFMeasuring the initial value of backup time Charging the batteryRecharging the battery Precautions and notes for operation OperationExplanation Start procedure Start and stop procedures and basic operationOperation Turn on the power switch of the UPS Operation after a power failure Setting switch 1 can be used to turn the beeper ON/OFF.Stop procedure Operation during recovery from a power failureConnection capacity/battery level meter Interpreting beeps and displays Displays and beeps in normal operationDisplay and beep for battery replacement Suspending a beep UPS functionsSelf-diagnosis test Description of the auto battery test function Changing the setting of the functionsSetting switch function list UPS functions BS signal reception time corresponds to the setting switch BS signal valid range setting setting switch Settings available for this operation are shown below UPS operation mode settingsSettable items and explanations OFF Settings Cold start Estimated backup time Measuring the backup timeHow to measure backup time For Windows Server 2003/XP/Me/2000/Windows NT/Linux/MacBUM100S Life of battery estimated replacement timing Maintenance and InspectionChecking the battery Methods for checking the batteryReplacing the battery Battery recycling Procedure for recycling the batteryDo not hold the connector or cable of the battery pack Tighten the 2 screws Battery replacement is now complete Red tape Tighten 2 screws After replacing the battery during operation Replacing the fan Do not put your fingers into the fanFan replacement procedure Cleaning Cleaning the UPSUsing the UPS monitoring software and contact signal UPS monitoring softwareSoftware title Connect the UPS to a computer RS-232CWhen using UPS Power Manager UPS monitoring software for Mac When connecting 2 or more computers to the UPSExplanation Install the included UPS service driver on the computer Connector Perform UPS service setup ClickRecycling and Discarding the Battery Stopping the UPSHow to set up UPS service set the time to shut down Windows Check Set ClickCheck Set Check Set Signal output Contact signalContact Signal Low battery level signal output BLItems that can be set using the contact signal card Remote ON/OFF SignalOutput delay time setting for backup signal output BU BU/BL signal reverse output settingInsert/ removal method of contact signal card Contact Signal Connector female DSUB9PContact Signal circuit inside the UPS Remote ON/OFF connectorContact Signal ratings Example of the use of the Contact Signal circuitPrecautions and notes for the use of the Contact Signal Remote ON/OFF circuitUsing an SNMP/Web card Adding an SNMP/Web cardSpecifications Description featuresSNMP/Web card outline Extending the backup time Connecting an additional battery unitAdding BUM300S to the BU3002SW Troubleshooting Problem Check and remedySpecifications ReferencesDimensions BU3002SWCircuit block diagram Related productsK1L-D-06051B