Figure 1. Fiber Link Data Connections

DATA EQUIPMENT

FIBER LINK

DATA OUT DATA IN

DATA IN DATA OUT

Figure 1. Terminal Block Pin Assignments

54

6

 

 

 

 

 

3

 

 

 

 

7

 

 

 

 

2

 

 

8

 

 

 

 

1

 

 

Using the breakout box

A breakout box with a 3’ CAT 5 patch cord (supplied) can be used to interface to the Phoenix system. Pinouts are shown in the tables and figures above.

Figure 2. RJ45 Socket

(Viewed from the rear of the unit)

Pin

1 8

RJ45-A

RJ45-B

RJ45-C

RJ45-D

8

Image 10
Contents Installation instructions Installation Instructions Customer Support Before You BeginIntended Use Conventions Used in this ManualGetting Started Installing Power SuppliesModule Installation OverviewTools and materials required Installing the Optical Transceiver ModuleInstallation instructions Connect fiberRepeater Connect Point-to-Point ConnectSelf-Healing Connect LED operating status Optic LEDConfigure data module Installing the Data ModuleSetting Mode Install data module ConnectUsing the breakout box Fiber Link Data ConnectionsPin Signal RS-485 4-WIRE Interface Data module channel sequenceInstalling the Ethernet Module Install the Ethernet moduleConfigure Install video input module Installing the Video ModuleInstall video output module Video Inputs Connection instructionsVideo Outputs Video Input module channel sequence Video Output module channel sequenceInstalling the Audio Module Configure audio moduleInstalling audio modules Channel sequence is as followsConnecting to audio modules Audio module channel sequence Terminal Block Pin AssignmentsInstalling the Contact Closure Module Install contact closure moduleConnect to the module RJ45 Socket Viewed from the rear of the unitContact Input module channel sequence Configuring the Phoenix Fiber Optic Communications System Turn on power and check status Select the system topologyGE Security Set the Node ID Front Panel Menu Tree and Descriptions Main Local Main MenuMain Local Node Main Local Node ID Main Local Node TopologyMain Local Optics Transmit Main Local Node Load DefaultsMain Local Optics Main Local Optics ReceiveMain Local Video Main Local Optics InfoMain Local Video Input Mapping Main Local Video Output Mapping Video Test Channel Test Off Format Ntsc Main Local Data Main Local Data Input MappingMain Local Data Output Mapping Main Local Data Format Select Main Local -Ethernet Port Control Main Local EthernetMain Local Ethernet Port Status Main Local -Ethernet Port TrafficMain Local Audio Input Mapping Main Local AudioMain Local Audio Output Mapping Main Local Contacts Main Local Audio TestMain Local Contacts Input Mapping Main Local Contacts Configure Main Local Contacts Output MappingMain Local Power Main Local TestMain Local Test Video Main Local Test LED/LCD/AlarmMain Local Test Temp Main Local Test DataMain Remote Main AboutBlank Panel Installation and Specifications Overview Limited warrantyOptical Transceiver Module Specifications Product orderingData Module Specifications DataEthernet Module Specifications EthernetVideo Module Specifications VideoAudio Module Specifications Product 0rderingContact Closure Module Specifications Contacts / Relays